Flow Turbine adapter change on a Worcester Bosch

  Рет қаралды 35,334

CP Utility Solutions

CP Utility Solutions

3 жыл бұрын

DISCLAIMER:
This video is only intended for use by qualified Gas Safe Registered engineers. You must not attempt any work on your boiler if you are not qualified. You must always carry out 26.9 checks upon completion of works on a boiler.
~
This is a common fault on these boilers, the flow turbine adapter is weak plastic and often fails. The tell-tale sign is the constant drip from the flow turbine housing.
Don't make the mistake of changing the actual flow turbine as it's rarely the problem, but usually only the adapter which costs around £3 or so.
Make note of the orientation of the adapter and the flow restrictor as if you put it back wrong it won't go fully home and will leak.
The clip can be a pain, but there's a knack to it and again long nose pliers help!

Пікірлер: 79
@PG_Clips
@PG_Clips 4 ай бұрын
Had this part leaking but had the flu so didn’t feel like fixing it myself. Had the boiler company round, showed them where it was leaking from, wanted to leave straight away without even opening the boiler as he was convinced he knew exactly what the problem was. Told him to at least take the cover off and look. 1 minute later, the cover was back on and still certain the housing was cracked. They sent me a quote for £400, to include changing the automatic air vent and the entire turbine housing. This did not include replacing the part that was actually leaking!! Have just repaired my boiler following this video. Nice and straightforward, easy to follow, perfect mate!
@cputilitysolutions
@cputilitysolutions 4 ай бұрын
👍🏾
@gsraja2966
@gsraja2966 3 жыл бұрын
Another great video 👍 I appreciate the time and effort that goes into them. Cheers👏
@markmcluskey9954
@markmcluskey9954 Ай бұрын
THANKS! Great video, saved me time and money, appreciated
@cputilitysolutions
@cputilitysolutions Ай бұрын
👍🏾
@Mark-ob9bk
@Mark-ob9bk Жыл бұрын
Thanks for this. Helped me on my first fix. I wouldn't have got all the bits otherwise
@cputilitysolutions
@cputilitysolutions Жыл бұрын
Glad it helped
@SouthernandSons
@SouthernandSons 2 жыл бұрын
Great video just got me out a hole on a job perfect 👊👊👊
@cputilitysolutions
@cputilitysolutions 2 жыл бұрын
Yes mate!
@charlieb8582
@charlieb8582 3 жыл бұрын
Good stuff mate , great content. Keep it uo
@cputilitysolutions
@cputilitysolutions 3 жыл бұрын
Thank you mate 👍🏽
@mrbal970
@mrbal970 3 жыл бұрын
Great video bro keep up with the good content 😀👍
@cputilitysolutions
@cputilitysolutions 3 жыл бұрын
Thank you!
@pinnerbright6303
@pinnerbright6303 Жыл бұрын
Where did you get the flow turbine adapter from?
@paulrossiter9567
@paulrossiter9567 3 жыл бұрын
Nice work....👏 have you any fault finding scenarios to upload 😁 would be good viewing 🙏
@trickym5748
@trickym5748 7 ай бұрын
Great video thanks will update when I get the part 👍
@cputilitysolutions
@cputilitysolutions 7 ай бұрын
Nice one 👍🏾
@trickym5748
@trickym5748 7 ай бұрын
@@cputilitysolutions Changed this part yesterday didn’t take too long leak free boiler now happy days 👍
@cputilitysolutions
@cputilitysolutions 7 ай бұрын
@@trickym5748 happy days 🙌🏾
@faroyoussef1757
@faroyoussef1757 Жыл бұрын
Have you changed the seals ? Or just the adapter to stop the leak ?
@s1evec
@s1evec 5 ай бұрын
Great video changed mine still no hot water central heating is fine though and thoughts greatly appreciated.
@cputilitysolutions
@cputilitysolutions 5 ай бұрын
Could be the turbine itself, would need further investigation
@tsalazar3289
@tsalazar3289 10 ай бұрын
Thanks I had exact same issue 👍
@cputilitysolutions
@cputilitysolutions 10 ай бұрын
Nice one
@ashhussain6965
@ashhussain6965 2 жыл бұрын
Life saver watching this video today
@DavidWestPhotographer
@DavidWestPhotographer 2 жыл бұрын
This is so helpful, can you tell me do I need to drain entire system to change this adapter?
@cputilitysolutions
@cputilitysolutions 2 жыл бұрын
Just isolate the incoming cold 👍🏽
@yensabi
@yensabi 3 жыл бұрын
Good stuff....👍
@subscriptions6867
@subscriptions6867 2 жыл бұрын
I don’t have a leak, but Need to open Hot Water tap to Maximum to get the Boiler to come on! Would replacing the flow turbine adapter help? Thanks!
@shayp8292
@shayp8292 2 жыл бұрын
Was it the flow sensor which he removed early on in this vid?
@shadow_bandit403
@shadow_bandit403 2 ай бұрын
Where does the fibre washer go?
@richienorthcott
@richienorthcott 8 ай бұрын
Thanks - just changed on mine, as you say the part which screws on is made of finest German cheese
@cputilitysolutions
@cputilitysolutions 8 ай бұрын
Haha you know it 👌🏾
@richienorthcott
@richienorthcott 8 ай бұрын
Leak was actually coming from the rear not the front - so as I feared I'm going to need to change the whole return manifold.This was worth a shot though - and this part doesn't come with the manifold kit so would have needed a new one anyway!
@cputilitysolutions
@cputilitysolutions 8 ай бұрын
@@richienorthcott make sure you get a new PRV as well. I've got a video on the right hand block as well if it helps 👍🏾
@richienorthcott
@richienorthcott 8 ай бұрын
@@cputilitysolutions Yup I'd already seen that, thanks again! There's limescale buildup looking very much like the one you show. Water is actually dripping from the LHS of the boiler case which had me confused - turns out the boiler is installed slightly on the p*ss so water is downhill along the metal bar where the pipe connections attach. The RH block is definitely the culprit.
@reliabill87
@reliabill87 2 жыл бұрын
What was the fault coming up for you to change the flow turbine?
@cputilitysolutions
@cputilitysolutions 2 жыл бұрын
It was leaking
@ashwood715
@ashwood715 2 ай бұрын
Does anyone know if the flow turbine can go in the other way round? This has recently been replaced on my boiler and now when I place a call for hot water the boiler kicks off with a creeping U0-U9 error code as if the temperature has raised too much
@cputilitysolutions
@cputilitysolutions 2 ай бұрын
You might have a blocked plate too
@ashwood715
@ashwood715 2 ай бұрын
@@cputilitysolutions cheers mate, is this likely easy to flush? Or complete new part?
@cputilitysolutions
@cputilitysolutions 2 ай бұрын
@@ashwood715 you can take it out and clean it with acid or replace it
@ashwood715
@ashwood715 2 ай бұрын
Cheers mate. Very helpful
@hawkingwestmids5738
@hawkingwestmids5738 5 ай бұрын
Any idea with this mate my greenstar 25si when I run hot taps or shower boiler locks out, I've replaced the heat exchange plate and still having the same issue ?
@hawkingwestmids5738
@hawkingwestmids5738 5 ай бұрын
Also replaced the hot water temperature sensor
@cputilitysolutions
@cputilitysolutions 5 ай бұрын
Does it run ok on heating?
@hawkingwestmids5738
@hawkingwestmids5738 5 ай бұрын
Yes mate totally fine on heating mode doesn't lock out
@hawkingwestmids5738
@hawkingwestmids5738 5 ай бұрын
I've just run the hot tap and felt the flow pipe which felt like it was starting to warm up so going to change thr diverter and paddle. But would this cause the boiler to lock out?
@cputilitysolutions
@cputilitysolutions 5 ай бұрын
@@hawkingwestmids5738 I wouldn't have thought so mate but best to rule it out. Let me know how you get on
@davebeddows6139
@davebeddows6139 Жыл бұрын
I can’t get that bloody clip back in for the life of me!!!
@cputilitysolutions
@cputilitysolutions Жыл бұрын
Don't give up mate! Make sure the turbine is pushed in all the way home
@tyronewest8163
@tyronewest8163 Жыл бұрын
Thank you brother 💯👊🏿
@cputilitysolutions
@cputilitysolutions Жыл бұрын
Nice one
@rkheatingcoolingservicesin9344
@rkheatingcoolingservicesin9344 7 ай бұрын
I had to do the same but then I got the F0 error
@cputilitysolutions
@cputilitysolutions 7 ай бұрын
What was the F0 about?
@Mchy0
@Mchy0 2 ай бұрын
Any one commenting here Robbed and expensive ect, don’t forget to become gas Engineer is nightmare, so much study lots of money to go training than qualified to work on gas appliances
@cputilitysolutions
@cputilitysolutions 2 ай бұрын
Spot on 👌🏾
@hawk_ness
@hawk_ness 9 ай бұрын
Just been charged £120 to have this replaced... Been robbed!
@cputilitysolutions
@cputilitysolutions 9 ай бұрын
That price is fair, it's what I would charge for the job.
@MrJ2theC
@MrJ2theC 7 ай бұрын
What's wrong with that?
@hawk_ness
@hawk_ness 7 ай бұрын
@@MrJ2theC Well they charged me £40 for a £5 part that I could have picked up locally that day vs the guy taking 5 days after ordering it online... The labour is what it is. Thats his wage for the 20 mins he was here.
@trickym5748
@trickym5748 7 ай бұрын
Just been quoted £110 to get this done
@trickym5748
@trickym5748 7 ай бұрын
Just ordered mine from screwfix £12.49 next day delivery I’m not paying £100 + to have fitted
@baitrunner1000
@baitrunner1000 Жыл бұрын
Black cheese they are made of 😆
@cputilitysolutions
@cputilitysolutions Жыл бұрын
Indeed!
flow turbine adapter
5:23
Geoffrey Needs training
Рет қаралды 28 М.
Return manifold replacement for a Worcester Bosch greenstar 30si
18:05
Boilers To Bathrooms
Рет қаралды 15 М.
МАМА И STANDOFF 2 😳 !FAKE GUN! #shorts
00:34
INNA SERG
Рет қаралды 4,9 МЛН
버블티로 체감되는 요즘 물가
00:16
진영민yeongmin
Рет қаралды 115 МЛН
КАРМАНЧИК 2 СЕЗОН 7 СЕРИЯ ФИНАЛ
21:37
Inter Production
Рет қаралды 530 М.
Worcester Bosch PRV change - the easy way!
5:31
CP Utility Solutions
Рет қаралды 60 М.
Worcester Bosch 30si/28i junior flow adaptor replacement
8:53
Boilers To Bathrooms
Рет қаралды 6 М.
Worcester Bosch fan change
13:32
CP Utility Solutions
Рет қаралды 18 М.
МАМА И STANDOFF 2 😳 !FAKE GUN! #shorts
00:34
INNA SERG
Рет қаралды 4,9 МЛН