Yearly Fire Extinguisher Inspection

  Рет қаралды 79,165

BYUI Fire Safety

BYUI Fire Safety

7 жыл бұрын

In this video, Cheston Farley so beautifully demonstrates how to perform a yearly inspection on a fire extinguisher at BYU-Idaho. Isn't his voice angelic?

Пікірлер: 74
@realmickmanning
@realmickmanning 4 жыл бұрын
Thanks for this. I've been paying someone big money to do it for me. Hell, this is easy. Cheers!
@gurgy3
@gurgy3 4 жыл бұрын
This is only the annual. Every 6 years you WILL need a professional to replace the media inside the tank. Every 12 years a cylinder test is required.
@marclee2453
@marclee2453 3 жыл бұрын
It has to be performed by someone permitted annually. You can't perform maintenance on your own and after watching this video it is now crystal clear why that is the case. In a millisecond he should have pulled that extinguisher from service.
@gillybuzz
@gillybuzz 2 жыл бұрын
you're paying for the liability to be on them not you lol
@peytonsedberry9747
@peytonsedberry9747 6 жыл бұрын
I can't believe you actually put this on youtube with the gauge and label being so misaligned!
@alvagood2693
@alvagood2693 6 жыл бұрын
If the gauge is not a threaded type gauge and only retained by a wire clip then all it takes is to turn the gauge in any direction which can possibly cause it to then lose pressure.
@LoneWolf1965
@LoneWolf1965 5 жыл бұрын
Did you check the date of manufacture or last hydro/6 year date? Did you actually blow out the hose? Was the label lined up with the gauge? Did you document the date of the extinguisher and serial number? As a licensed fire extinguisher tech I would not have passed this fire extinguisher.
@mellyomukuenambura5081
@mellyomukuenambura5081 5 жыл бұрын
hi can you send me the inspection sheet the you use
@marclee2453
@marclee2453 3 жыл бұрын
@@mellyomukuenambura5081 Good morning. Did you ever get a fire extinguisher inspection form?
@Asertix357
@Asertix357 Жыл бұрын
I'm ashamed of how long it took me to understand these annual inspections were for extinguishers in businesses and commercial buildings.
@billt689
@billt689 3 жыл бұрын
Question for the professionals with a hydro test. I understand it is every 12 years off manufacturers date but let’s say a new 2008 fx that wasn’t 6 year maintenanced u til 2017 for some reason. Would you still do the hydro test in 2020 or 6 years after the first 6 year maintenance in 2023?
@marclee2453
@marclee2453 3 жыл бұрын
Yes. There is no wavering on 12 year hydro test
@charlesk1140
@charlesk1140 2 жыл бұрын
Yes you would still have to do the Hydrotest in 2020. Usually what I do for customers in cases like this is if its within two years I will go ahead and hydrotest it so they dont have to pay twice. For example if the FE was new in 2008 and nothing was done to it until 2019 (assuming the FE is in good condition) then I would go ahead and perform the hydrotest on it(1 year early). If I only did the 6yr then the customer would then have to pay AGAIN for the recharge and hydrotest the next year. By going ahead and doing the hydrotest on it in 19 it saves the customer from basically having to pay twice in back to back years for the recharge. Also, doing this would also change the 12 year hydrotest cycle for the FE. The new test dates would now be the 6yr maint. test would now be due in 2025 and the 12yr hydrotest now due in 2031.
@heckeroffical3862
@heckeroffical3862 Жыл бұрын
Wow this was in 2017
@MarMarGeo
@MarMarGeo 6 жыл бұрын
I would remove this video before customers start reading comments. Lol
@ahmedhamd2708
@ahmedhamd2708 5 жыл бұрын
Hhahahahah truth
@Reaglesracing44_
@Reaglesracing44_ Жыл бұрын
can a broken gauge be replaced when it’s under pressure?
@Zopso
@Zopso Жыл бұрын
No
@zacharyrivera6040
@zacharyrivera6040 6 жыл бұрын
I would not have passed this extinguisher. The gauge should be aligned with the nameplate right in the middle just like when it is new. Whoever rebuilt this extinguisher might have used the wrong o ring and that’s why it’s off.
@P25AES
@P25AES 6 жыл бұрын
Zachary Rivera Agree 100%
@alvagood2693
@alvagood2693 6 жыл бұрын
Same observations. Looks to me like a non rechargeable extinguisher.
@P25AES
@P25AES 6 жыл бұрын
It is definitely a rechargeable extinguisher based upon the red pressure guage.
@MikeMcG58
@MikeMcG58 4 жыл бұрын
I wouldn't call it a "zip tie" either. That can be confusing.
@titozatarra8112
@titozatarra8112 3 жыл бұрын
Ehhhh. That looks like an aftermarket label. That's not a factory Ansul label. The person who applied the "new" label probably put it on crooked. If not, I agree.
@alvagood2693
@alvagood2693 6 жыл бұрын
What is an annual inspection. There are monthly or more often inspections. Annual is maintenance done only by a certified person per many state and local fire codes.
@cijadafridi4496
@cijadafridi4496 5 ай бұрын
that is lev4 inspection
@greatmusicgoodfeel826
@greatmusicgoodfeel826 5 жыл бұрын
Wow to many want to be professionals commenting .. he is doing the job as any inspection would be doing BUT some would just install the tag without doing their job right. See it all the time .
@marclee2453
@marclee2453 3 жыл бұрын
No. Everyone is being kind. This guy has no clue.
@loopyu2y
@loopyu2y Жыл бұрын
same with trucks they pass inspection and then there flying off tire kills someone on the highway road. Point being dont skip any steps to save time. Peoples lives are on the line.
@byronhayes1217
@byronhayes1217 3 жыл бұрын
Lol. My buddy just started servicing fire extinguishers. He doesn't know the difference between feet and inches on paper. Sounds like a hard job.
@thefrub
@thefrub 3 жыл бұрын
Naughty fire extinguishers with solidified propellant get spanked
@solomann940
@solomann940 3 жыл бұрын
I thought the hose check should be done annually
@jayhouse345
@jayhouse345 6 жыл бұрын
Great video. You only missed two things. 1st, NFPA 10 - 7.3.2.2 says the tamper seal shall be removed by operating the pull pin. You removed the tamper by hand then operated the pull pin. 2nd, you forgot to weigh it. Other than that great video.
@billt689
@billt689 3 жыл бұрын
Imagine weighing every extinguisher in a building with 100+ fx
@jayhouse345
@jayhouse345 3 жыл бұрын
@@billt689 If you don't weigh them then you are not following NFPA 10.
@billt689
@billt689 3 жыл бұрын
@@jayhouse345 we don’t weigh them unless they need maintenance it if they r just getting a tag
@jayhouse345
@jayhouse345 3 жыл бұрын
@@billt689 You can "hefty" weigh them for the monthly inspection, but if you are not weighing them during the annual maintenance you are not following NFPA 10.
@jayhouse345
@jayhouse345 3 жыл бұрын
@@ricardovega6252 Since you are asking this question that tells me you have not read NFPA 10 and the manufacturer's service manual.
@jimgardner6018
@jimgardner6018 2 жыл бұрын
Definitely the wrong head, got mixed up with another when recharging, you can also see the hydro sticker directly behind head….. so at one time it was good…. I wouldn’t have used this extinguisher while doing a video!
@julietmikeoscar
@julietmikeoscar 6 жыл бұрын
Zip Tie?! I believe you mean “Tamper Seal”... Even if you understand it isn’t an actual zip tie, you should be careful not to cause confusion to anyone watching this video that is unfamiliar with fire extinguisher service & Safety.
@alvagood2693
@alvagood2693 6 жыл бұрын
We had a customer that would install zip ties rather than contact us to service the unit so they could save money. OSHA cited them for each extinguisher they had put zip ties on. Prior to OSHA, the local AHJ had contacted us as to why we were using zip ties instead of tamper seals. Myself and the AHJ met with the district manager of the company. I informed the district manager that I was obligated to remove our tags from the zip tie units. I had a hand held digital scale attached to the pull pin and the scale registered 27 pounds of pull before the zip tie broke. The district manager authorized our firm to correctly service every store in her district. Two days later the main office authorized us to provide service in everyone of their stores in the state and to be the ones to provide new Class K extinguishers rather than the stores provide them due to gauge damage from being shipped horizontal instead of vertical.
@pauljonker673
@pauljonker673 Жыл бұрын
There is no requirement to 'fluff' the extinguisher. The powder inside has been specifically designed to not pack down, even after many years of being in service. Additionally, flipping a pressurized vessel upside-down can be dangerous if it slips and falls, not to mention hitting it with anything. Manufacturers have released many statements saying the practice of fluffing the extinguishers is not recommended.
@aidenlui2056
@aidenlui2056 Жыл бұрын
It might be a requirement for the company
@Wa3ypx
@Wa3ypx Жыл бұрын
I see who ever had it apart last, got valve bodies mixed up or the wrong o-ring. The gauge face is too far off the center line of the label.
@e-curb
@e-curb 3 жыл бұрын
You also need to check the gauge to see that the needle is in the green zone.
@fsb_-bf3th
@fsb_-bf3th 2 жыл бұрын
Around the 1:50 mark he mentions it
@Screwdriversteve1
@Screwdriversteve1 4 жыл бұрын
Gauge is not in alignment with the instructions, Doe the extinguisher need a HST? does the extinguisher need a 6 year inspection??? So much wrong with this video.
@rabee2040
@rabee2040 4 жыл бұрын
U fluffer !!!!
@IsabelRoblesmontilla
@IsabelRoblesmontilla 4 ай бұрын
Z
@robertknemeyer2184
@robertknemeyer2184 2 жыл бұрын
I can follow the comments and verify everything wrong on here, but what tells me these guys are rookies is… 1. Calling a supervisor for things the tech should know and 2. They are using BECO Lube
@bronco_b
@bronco_b 3 жыл бұрын
Gauge isn’t aligned. Wrong O ring from person who previously serviced it. Failed
@landonstreet1601
@landonstreet1601 4 жыл бұрын
That extinguisher is very misaligned. Use the proper o-rings.
@AngelMartinez-yj3sm
@AngelMartinez-yj3sm 3 жыл бұрын
Landon Street OR 28 o-ring ?😂
@FireAlarmTech7.
@FireAlarmTech7. 2 жыл бұрын
It’s Not always the o-rings, it could be a different head from another unit that has different threading. Never mix up heads, or your extinguishers won’t be aligned properly.
@ricardovega6252
@ricardovega6252 2 жыл бұрын
@@FireAlarmTech7. some fire extinguishers are really hard to align back ,like the sentry fire extinguishers,those you need to tighten really hard
@MarMarGeo
@MarMarGeo 6 жыл бұрын
That’s a fail!! Wrong rubber seal. #fail
@kingt-baby1523
@kingt-baby1523 5 жыл бұрын
Don't hate.... Learning = $$$ now you can apply for a job doing this same easy work making easy$$$$ 079 CHI TWN SS
@Wa3ypx
@Wa3ypx Жыл бұрын
I'll take you out to the land fill and have you crawl up on a D-9 dozer when its 20 degrees just to find a part broken on a 20 lb. ABC. Slog back to the cold truck to make a repair and walk it back. Yeah its a license to print money. Right now I'm wiping my ass with 20s only because I ran out of 50s.
@JuanHernandez-gf6te
@JuanHernandez-gf6te 4 жыл бұрын
That one should never got tag good
@alvagood2693
@alvagood2693 6 жыл бұрын
False information, each particle is pressurized preventing packing. inverting, pounding on the bottom can cause the chemical to enter the pressure gauge to the point of preventing the internal pressure to correctly be indicated at the gauge thus showing full pressure in the extinguisher, or no pressure at all. Manufacturers of extinguishers have issued bulletins about this practice.
@jayhouse345
@jayhouse345 3 жыл бұрын
Wrong.
@marclee2453
@marclee2453 3 жыл бұрын
Pretty sure thats is a incorrect statement. But this whole video is full of incorrect statements so don't worry about it. Needs to be removed.
@DCMARTIN
@DCMARTIN Ай бұрын
So many mistakes done by the technician. NO ONE should only visually inspect the tank and the hose, turn it up side down for a minute, throw a new tag on and claim it passed. Why didn't you discharge it? Why didn't you wash the tank? Why didn't you use an air gun, pressure clean the inside of the tank and inspect the inside with a light? Why did you not inspect the o-ring's? Please, no one just do what this guy did and think that the tank is passed with safety. This must of been a joke video!
Inspection and testing of fire extinguishers
26:32
Axiom Compliance Learning
Рет қаралды 17 М.
#Recharge dry powder fire #extinguisher 6kg
2:30
Thermodinamiki Asikis.D
Рет қаралды 120 М.
100❤️
00:19
MY💝No War🤝
Рет қаралды 23 МЛН
Зачем он туда залез?
00:25
Vlad Samokatchik
Рет қаралды 3,2 МЛН
Multi-purpose Fire Extinguisher Inspection and Use
6:21
UVA TTA
Рет қаралды 60 М.
The shocking truth behind fire extinguisher production
13:23
production media
Рет қаралды 3,4 М.
How to do a 6 Year Maintenance/Recharge A Fire Extinguisher
15:21
FireAlarmDude5967
Рет қаралды 26 М.
Paul servicing a fire extinguisher
13:27
AllAmericanFireProtectionUSA
Рет қаралды 6 М.
Fire Extinguisher Inspection
2:20
Silco Fire & Security
Рет қаралды 33 М.
How to perform a six year fire extinguisher inspection
2:43
Crisp LaDew
Рет қаралды 101 М.
REFILLING OF FOAM FIRE EXTINGUISHER HAVING CO2 CATRIDGE
4:24
MERCHANT SHIPS knowledge
Рет қаралды 7 М.
Fire Extinguisher Hydrostatic Pressure Test
22:22
Erick Hernandez
Рет қаралды 42 М.
Fire Extinguisher Service - 6 Year Maintenance Part 1
3:43
Heath Franklin
Рет қаралды 13 М.