Goodman Heat Pump Low On Refrigerant! Adding Leak Stop And Charging With R-410a!

  Рет қаралды 14,486

Jeff’s HVAC Adventures

Jeff’s HVAC Adventures

Жыл бұрын

In this video I add One and Done Leak Sealant to a Goodman Heat Pump and top off it’s refrigerant charge with R-410a.
Like and Subscribe

Пікірлер: 64
@thewibb
@thewibb 28 күн бұрын
FINALLY someone purging the hoses correctly. Awesome video sir 😎
@anthonylosego
@anthonylosego 10 күн бұрын
32.8 F, you're close to freezing your evaporator coils. It's possible in the condition it was in the customer lowered the thermostat. Could be a meat locker in there after recharging. And the leak stop didn't do that, it's the 3lbs you put in. You'll know (as a good tech) when you come back in 2 weeks to check the readings to see if it lost any refrigerant. I'm sure if the owner came home to a meat locker, he adjusted the stat. Could be poor air flow, but with a leak you probably just have a low charge situation. Leak stop is good on budget but as you said, a leak fix is better. I didn't see any caps on those Schrader valves so that might also be an issue. Core replacement is cheap and easy. Imagine putting leak stop in your compressor only to fix a leaky valve. lol
@israelolguin1156
@israelolguin1156 Жыл бұрын
I had Nu-Calgon Ultimate Easy Seal 7.5 ton with UV installed in my RUUD R22 system and the charge has been holding for almost a year now and the house is a lot cooler. I also keep my coils clean and a Merv 1 filter but I did have a slow leak in the evap and Easy Seal 7.5ton UV worked. I did my homework first.
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Good to hear!
@chesstime356
@chesstime356 Жыл бұрын
I think you will be going back to this house to take check blower motor wheel evaporator coil , TD and check static pressure . Nice video fully watch.
@ccthepope
@ccthepope Жыл бұрын
Nice information.
@joshuaricks7730
@joshuaricks7730 Жыл бұрын
I don’t understand how you can add any refrigerant without cleaning that condenser coil first
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
My thought was that I’d rather have the head pressure a little higher on the cooler day that I did this repair. As opposed to cleaning it, having a sopping wet coil and have my head pressure even lower. As you can see from my readings, even with a full charge the dirty coil didn’t effect the head pressure.
@darylfortney8081
@darylfortney8081 15 күн бұрын
Added it to my old r-22 that had a very slow leak and haven’t had a problem since. Been a few years.
@JeffsHVACAdventures
@JeffsHVACAdventures 15 күн бұрын
Good to hear
@Zepsswansong
@Zepsswansong 2 ай бұрын
I would think the time the unit was running with a low charge while you were putting in the one and done, the evap coil frosted over, creating the issue of low evap pressure. When this happens, you only had to kill the condenser power for about 5 minutes, then you would have thawed the coil and pressure should come back up. That could have been verified by looking at the condensate drain and you would see that surge of condensate water coming out for a minute then stopping. If that didn't happen, then i would say cold room, dirty evap coil, fan speed or TXV issue. Just my thoughts here, from 41 years of experience.
@EverythingHVACR
@EverythingHVACR Жыл бұрын
No load and possibly air flow, good call. Suction pressure rule of thumb saturation 30 -35 degrees less than entering air temp, so 65 degree space is possible.
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Good Rule of Thumb!
@arrealhandymanservice4459
@arrealhandymanservice4459 16 күн бұрын
That’s only for no load so if it’s 68 return air then the suction line temp should be arround 30
@EverythingHVACR
@EverythingHVACR 16 күн бұрын
@arrealhandymanservice4459 suction saturation would be 33 degrees at 68 degree return air, so any temperature over the SST "33" would be superheat. 30-degree suction line would indicate flooding.
@lanceditzler
@lanceditzler 6 күн бұрын
Awesome. The whole evap coil will be covered in dye.
@JeffsHVACAdventures
@JeffsHVACAdventures 6 күн бұрын
Guess we’ll know where the leak is then.
@mark.r8900
@mark.r8900 Жыл бұрын
Hi, it's a very time consuming process to find a leak. Customers need to pay more for this process? Thanks
@Sctronic209
@Sctronic209 10 ай бұрын
I use them occasionally.
@jrh86
@jrh86 Жыл бұрын
Great instruction and information as always, what are your thoughts on your testo gauges ??
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Love them. But the testo gauges, and testo smart probes are the only brand of electronic gauges I’ve used so I can’t compare them to others. I was on analog up until about 2 years ago.
@jrh86
@jrh86 Жыл бұрын
@@JeffsHVACAdventures thanks.👍👍
@anthonylosego
@anthonylosego 10 күн бұрын
@@JeffsHVACAdventures Fieldpiece is rock solid. Never used Testo.
@taglyo96
@taglyo96 11 ай бұрын
Where did you buy that Leak Stop+? What store? I can't find it anywhere. And why did you choose that sealer instead of others (like Easy Seal)? This info would be very helpful to me. Thanks for the video!
@JeffsHVACAdventures
@JeffsHVACAdventures 11 ай бұрын
United Refrigeration is where I got the leak soap and the One and Done. Really only used this brand because it was available. But I do use Easy Seal exclusively now.
@taglyo96
@taglyo96 11 ай бұрын
@@JeffsHVACAdventures Thanks Jeff! Much appreciated sir!!!
@rolohern9645
@rolohern9645 3 ай бұрын
How is it use with 410a? Psi on the vapor line is usually in the 100psi and u need them to be under 65 psi. Thanks for the input.​@@JeffsHVACAdventures
@jpenn727
@jpenn727 Жыл бұрын
I want to see the results.
@maxpower8225
@maxpower8225 Жыл бұрын
Dirty evaporator or dirty air filter 👍
@H2ObarryField
@H2ObarryField 2 ай бұрын
What do you do if the low pressure switch is in lockout? Lennox system has a really slow leak. Plan to add sealant and then charge the system. However, can this be done when the compressor is off, due to the lockout?
@JeffsHVACAdventures
@JeffsHVACAdventures 2 ай бұрын
Bring the system up to full charge first and then add the sealant.
@H2ObarryField
@H2ObarryField 2 ай бұрын
@@JeffsHVACAdventures Thanks Jeff. Is it okay to charge the refrigerant when switch is in lockout? I assume that the 410 tank pressure will add enough to deactivate the lockout, but not sure.
@JeffsHVACAdventures
@JeffsHVACAdventures 2 ай бұрын
@@H2ObarryField yea, it should take a good 3-4 lbs with the system not running. Should be enough to close the LPS.
@H2ObarryField
@H2ObarryField 2 ай бұрын
@@JeffsHVACAdventures Thanks, Jeff. It worked!
@tommymein9046
@tommymein9046 8 күн бұрын
How can you possibly charge a system accurately with filthy coils like that?
@JeffsHVACAdventures
@JeffsHVACAdventures 8 күн бұрын
It didn’t affect the head pressure as much as you would think.
@1wash3r3
@1wash3r3 Ай бұрын
I paid someone to do the Max Seal Ultra and slso add 2lbs of R-22. He charged me $500 for the R-22 and $270 for the leak stopper. I was wondering if to high cost or this is average people are charging.
@JeffsHVACAdventures
@JeffsHVACAdventures Ай бұрын
Seems in line.
@chrisseabolt9593
@chrisseabolt9593 Ай бұрын
What color was the bottle of refrigerant
@darylfortney8081
@darylfortney8081 15 күн бұрын
Leak stopper is like $40 on amazon and can be done at the same time as adding r-22 so he worked you hard on that upgrade.
@darylfortney8081
@darylfortney8081 15 күн бұрын
Probably spent $30 in r-22 and should have taken all of 20 minutes to do.
@darylfortney8081
@darylfortney8081 15 күн бұрын
That coil really needed cleaning, even a complimentary water hose spray down
@vladmir3203
@vladmir3203 Ай бұрын
Before to do something you must to clean this dirty condenser!!! :)))
@anthonylosego
@anthonylosego 10 күн бұрын
Agreed.
@tman984
@tman984 Ай бұрын
how does this impact the lineset when it comes time to replace the entire system? gonna wreck the lineset?
@JeffsHVACAdventures
@JeffsHVACAdventures Ай бұрын
You should always change the line set when replacing the equipment when possible. But if you keep the same line set It wouldn’t bother it at all as long as you flush it properly.
@anthonylosego
@anthonylosego 10 күн бұрын
@@JeffsHVACAdventures Blow a cleaner peg through it.
@channah8966
@channah8966 27 күн бұрын
how we can buy that too
@JeffsHVACAdventures
@JeffsHVACAdventures 27 күн бұрын
United Refrigeration sells the One and Done brand
@james10739
@james10739 Жыл бұрын
Letting refrigerant flow into your lines then cracking for a purge seems pointless to me the air that was in your hoses has already mixed with the refrigerant its not like the air is just compressed and separate from.the refrigerant the only thing that makes sense is if you had the line loose when you hook up the high side hose then maybe the refrigerant could push out the air but like that ita already mixed
@anthonylosego
@anthonylosego 10 күн бұрын
Agreed. You need to open the high side and immediately purge. Otherwise, the air in your lines is leaking back into the system while you wait. The faster you purge after letting gas in the gauges the better. Ball valves are good for this, but you have to be quick while the pressure equalizes. Every second it is equalized allows air contamination to flow back into the high side connection. This is called diffusion. Higher concentrations move to areas of lower concentration by gas type. Hence, the air in the lines will bleed back into the system so long as the ball valve is open on the high side source. Minimizing the time the line is exposed to the high side source with air still in the lines is important. Bleed it quickly. Once you do that, you can take some time to push the stop leak in. A tiny bit is probably all that is required. You put a lot of liquid in the low side. I'd have turned it (the ball valve) each time very momentarily and do it half as many times as you did. Getting that last 3% of stop leak in there is less important than all that liquid on the suction side.
@tedzambrano8473
@tedzambrano8473 Ай бұрын
Some tech say it bad, will interfere and damage unit. Why can't they be on the same level, so much wishy-washy
@anthonylosego
@anthonylosego 10 күн бұрын
Sticky sealants stick to your compressor too. So it will shorten its life. Like stop leak on oil leaks in your car. Cheap, but no really good in the long run. Last ditch effort for more time.
@rolohern9645
@rolohern9645 3 ай бұрын
Don't get it! If u can't go inside the house,how is the ac on. If Temp inside is cold. Why is the ac running.
@anthonylosego
@anthonylosego 10 күн бұрын
62F degree day. The subcooling shown would keep it fairly cool even with that level for that day. So the owner left it on. The subcooling was so low, it was just keeping up but running constantly. No match for a 90F degree day though.
@rolohern9645
@rolohern9645 19 сағат бұрын
@@anthonylosego thanks for ur response.
@donaldcurtis9229
@donaldcurtis9229 2 ай бұрын
Took that little stem off.Guess what?The problem was the little Leo valve was stuck.That's how I lost all my refrigerator save myself a ton of money
@josrejonis7561
@josrejonis7561 Ай бұрын
this isn't a serious video right?
@JeffsHVACAdventures
@JeffsHVACAdventures Ай бұрын
Yes it’s a joke that only you understood.
@anthonylosego
@anthonylosego 10 күн бұрын
@@JeffsHVACAdventures I understand your pension for working with customers. But for better results, insist on leak fixes. I suspect the Schrader valves may have had a hand in this leak. Simple fix, but a leak check could result in a paying customer and do it right. Better in the long run for the customer.
@JeffsHVACAdventures
@JeffsHVACAdventures 8 күн бұрын
​@@anthonylosegoi do push for leak searches. Most of the time, customers cheap out and take the least expensive route. This particular customer actually just sold this house last week, so that's why he was so cheap on this repair last year.
Using Easy Seal To Stop A Refrigerant Leak!  Trying Out Other Nu-Calgon Products Too!
21:42
Where to Find R-22 & R-410A LEAKS on AC Units! Top 10 Spots!
14:46
AC Service Tech LLC
Рет қаралды 192 М.
Smart Sigma Kid #funny #sigma #comedy
00:25
CRAZY GREAPA
Рет қаралды 18 МЛН
Khó thế mà cũng làm được || How did the police do that? #shorts
01:00
Do Leak Sealers Actually Work?! HVAC Testing and Results
6:27
World of HVAC
Рет қаралды 11 М.
How I Add Refrigerant to an Air Conditioner
10:20
Fox Family Heating and Air Conditioning
Рет қаралды 366 М.
Insane HVAC heatpump leak repair?? or HUGE money saver$$$
11:08
Pair of Jacks
Рет қаралды 785
Converting R22 AC Unit to R422B. Plus Leak Search On 2 Units!
36:26
Jeff’s HVAC Adventures
Рет қаралды 13 М.
Leak Search Tips From Bert
17:50
HVAC School
Рет қаралды 68 М.
What Should my AC Pressures Be for R410A Refrigerant
5:27
Benjamin Sahlstrom
Рет қаралды 428 М.
Low Refrigerant? Freon Leak? Check This First!
7:02
Sam
Рет қаралды 426 М.
How to charge mini split yourself, DIY 410a refrigerant, save money!
4:47
Repair Leak in Air Conditioning System Using Easy Seal
6:18
David Jones
Рет қаралды 128 М.
Goodman A/C NOT COOLING!  More Than Just The Obvious!
14:47
Jeff’s HVAC Adventures
Рет қаралды 7 М.