How to remove a Worcester 25i erp hydroblock, replacing left or right side hydroblock on a Worcester

  Рет қаралды 7,748

Tomkat Gas Training

Tomkat Gas Training

Күн бұрын

Derek in this video shows trainee gas engineers how to completely remove the hydroblock on a Worcester 25i erp combination boiler to make it easier to work on the left or right hand side of the hydroblock. remember you must be gas safe registered to work on gas and competent to work on boilers to do tis task.
#best #gastraining #centralheating
• WORCESTER 25i ERP COMB...
Link for full version of the video

Пікірлер: 23
@rayc1503
@rayc1503 2 жыл бұрын
Great little tutorial Dez. I always find pumping up the vessel whilst draining aids removing alot of the residual water in the hydro manifold . You were fighting to remove that block 🤣 👍
@tomkatgastraining
@tomkatgastraining 2 жыл бұрын
I wish I filmed how easy it was to get back in 🤣
@grantswheelstohills
@grantswheelstohills 2 жыл бұрын
Hi Derek, thanks for this recent video. They really help, along with other subscribers comments. I have been gas safe for a good few years...but moving into servicing and the scary world of repairs! So these films help many thanks. Happy New year to you all.
@leonardbalint4930
@leonardbalint4930 2 жыл бұрын
Thanks Derek, please more similar videos . It helps. Happy New Year to you and Tomkat
@abuadammemon3968
@abuadammemon3968 2 жыл бұрын
Wow thank you so much in busy time,still manage to made very informative video. bless you Derick (you always solve the problems and giving good info Specially Regulations)
@abuadammemon3968
@abuadammemon3968 2 жыл бұрын
🌟🌟🌟🌟🌟
@stuartsteel1
@stuartsteel1 2 жыл бұрын
I've had so much much practice at this it doesn't faze me now.
@leaturk11
@leaturk11 2 жыл бұрын
Great video Derek
@samchappell233
@samchappell233 2 жыл бұрын
Great video 👍👍
@gasfitter78
@gasfitter78 2 жыл бұрын
Great video again. You made it look easy but we all know a boiler that has been in situ for 5 years or more it's not so easy. I would also suggest to put the boiler into service mode to aid with drain down cause it moves the diverter valve in to mid position also if a boiler has deaeration function best practise to use it.
@vmax1399
@vmax1399 2 жыл бұрын
You're a god I have done a few of these never as quickly as you and some of them can be real bastards anybody doing it need to watch out for Sharp sheet metal in the boiler case also real handy to have a wet Vek there and if you're feeling really sharp take the cap off the expansion vessel check and if necessary pressure it back up it's quite possible by the time you get to take the Hydro block out will be worn out you could check that before you drained and strip the boiler by pressing the shrider valve if you get water out it is clucked and you can have the conversation with the customer befor trying to haggle after the boiler strip down.This will save you the embarrassment of having the ev going glug glug this happens sometimes even after draining not trying to be cocky just to help the youngsters .
@darrenclarke161
@darrenclarke161 2 жыл бұрын
Handy vid this can seem scary especially for the first time . 👍
@dvsnbanda
@dvsnbanda 2 жыл бұрын
T Great video
@viktorroswell1041
@viktorroswell1041 2 жыл бұрын
Try it in the back of a cupboard and it's been in for more then 5years not so easy, got the scares to prove it!
@tomkatgastraining
@tomkatgastraining 2 жыл бұрын
Like I said it was easy for me and yes I still have the scars from working on Worcester it’s what makes us great 😜
@stevehouse3904
@stevehouse3904 2 жыл бұрын
Yes, always pump the pressure vessel dry when draining and set div valve mid position, I also have my wet and dry plugged in ready to go if needed. Those seal kits aren't cheap either, they seem to have every O ring and clip on the boiler in them and you only use a few of them, unless there is a smaller pack, the fibre washers are unique to Worcester, standard ones don't seem to fit. Great video as usual.
@SuperWayneyb
@SuperWayneyb 2 жыл бұрын
🤘😎🤘👍👍
@eyyubgasimov2204
@eyyubgasimov2204 2 жыл бұрын
And sometimes harnesses are not coming out. Goshhh, not very much fan working on Worcester to be honest. Sometimes really easy things turn out to be nightmare. Not engineer friendly boiler I must say.
@timhancock6626
@timhancock6626 2 жыл бұрын
You certainly get plenty of practice replacing hydro blocks on WB boilers. They fail even with shock arresters fitted. It's because the plastics are crap....but hey, WHICH likes them so crack on....as it were 🤣
@rayc1503
@rayc1503 2 жыл бұрын
Truth be told Worcesters are assembled using the most cost effective parts and they haven't taken on board what installers on the field have said. They are however fantastic at product marketing. I reckon they could sell the public shit on a stick 🤣. Customers seem to have a preference and it's branded with a Bosch logo. That's until they have one installed 😏. Ideal on the other hand have took on board what installers have mentioned. They've progressed alot over the years 😊. Still have their flaws though. As to many other manufacturers.
@eyyubgasimov2204
@eyyubgasimov2204 2 жыл бұрын
Usually it is easier to take out parts, but putting them back again is a mission. Once I changed burner gasket, and because new gasket was thicker and sliding in the fan assembly back in its places, was nightmare.
@eazyrat
@eazyrat 2 жыл бұрын
derek! info is pukka but please get a decent mic and cam setup that intro blew my ears off! thanks
compact  service strip down
9:00
Geoffrey Needs training
Рет қаралды 22 М.
1 or 2?🐄
00:12
Kan Andrey
Рет қаралды 50 МЛН
Was ist im Eis versteckt? 🧊 Coole Winter-Gadgets von Amazon
00:37
SMOL German
Рет қаралды 36 МЛН
Worcester Bosch junior right hand hydro block
7:33
The Mental Gas man
Рет қаралды 1,5 М.
A simple water heater is more clever than it seems
22:52
Technology Connections
Рет қаралды 1,9 МЛН
Worcester Bosch ERP Plate Heat Exchanger
10:49
CP Utility Solutions
Рет қаралды 7 М.
Return manifold replacement for a Worcester Bosch greenstar 30si
18:05
Boilers To Bathrooms
Рет қаралды 15 М.
Worcester Bosch Boiler Leaking - Leeds Plumber
32:41
Allen Hart
Рет қаралды 76 М.
How To Remove A Worcester Bosch Plate Heat Exchanger...Quickly!!
14:33
Blue Bulldog Plumbing
Рет қаралды 6 М.
Worcester Bosch main heat exchanger/heat cell replacement
7:45
CP Utility Solutions
Рет қаралды 12 М.