How to replace a 12v UPS batteries with Lithium Batteries (LifePo4)

  Рет қаралды 36,446

Richie Salvador

Richie Salvador

3 жыл бұрын

I made a successful DIY Lifepo4 12v 32650 batteries to replace the dead lead acid battery of my UPS. Enjoy the video!
Materials used:
Aliexpress:
32650 Batteries - ali.ski/JioCPx
Nickel Tab Strip Wire - ali.ski/WIVNa
Battery Holder - ali.ski/6Sk0t
4s BMS - ali.ski/GPV06T
Soldering Kit: ali.ski/U3kjZ
Amazon:
4s BMS: amzn.to/3h228od
32650 Batteries: amzn.to/34vveXY
Soldering Kit: amzn.to/3nD0YSj
Battery Holder: amzn.to/3pajUZ2

Пікірлер: 163
@kristiqntachev7139
@kristiqntachev7139 2 жыл бұрын
The reason that it drops just suddenly is that LifePo4 cells have a flat discharge curve so all of a sudden one of the cells drops directly from 3.3 volts to 2.5 or less in a matter of seconds this means that it has like 10%-20% capacity left so if one cell drops bellow 2.5 or it may vary due to different BMS's the BMS itself is shutting of the connection to the negative terminal. U will not hear beeping or anything just will stop suddenly. The other cause is related to the first one if you are running without BMS it will work just fine but if one of the cells drops with 0.7 volts the ups doesn't have time to beep for low voltage. For example the Lead Acid batteries have a more curved like discharge curve so it will steadily drop from 13 to 12.9 to 12.8 to 12.7 and so on so the ups itself has time to beep. Cheers and be careful of what you are doing man u almost needed a fire extinguisher !
@richiesalvador9457
@richiesalvador9457 2 жыл бұрын
yep! lesson learned. my first time doing it :)
@samindaperamuna6392
@samindaperamuna6392 Жыл бұрын
This
@averagestudent4358
@averagestudent4358 7 ай бұрын
So your advice is to throw away the old ups with faulty battery? I've one.
@imark7777777
@imark7777777 3 ай бұрын
Na a bucket of sand and an explosion containment pie dish. Then the fire extinguisher.
@zagnut48219
@zagnut48219 2 жыл бұрын
good choice using LiFePO4 as a replacement. This chemistry is the only viable option when needing a replacement for 12v PB. LiFePO4 has a lower nominal voltage, where other chemistries, such as Li-NCA or Li-NCM, voltage can be too low at 3S or too high at 4S.
@5_Is
@5_Is 3 жыл бұрын
A home computer UPS is a "stand-by" (as opposed to the more expensive "continuous"} power backup. This means that devices connected to it run directly off the grid mains until an interruption of current is sensed, at which point the battery-driven inverter is switched on (in a "continuous" UPS, the output is always from the inverter and the battery is constantly under load while the device maintains its charge and the grid mains is isolated from the connected equipment). The switching is nearly instantaneous, happening in five milliseconds or less, at which point the battery will begin discharging. This state will exist until the UPS senses a return of house power or the unit shuts down to avoid over discharging the battery. Once the unit again is powered by the grid mains, a charging sequence is initiated to bring the battery up to full charge which returns the unit to a back-up stand-by status mode with the house current again passing through to the connected device(s). The important consideration here is any UPS is designed to work with a specific battery chemistry, in this case the AGM lead acid. There are numerous articles available that explain in depth why one should not misuse a charger meant for one type of battery to charge a different battery chemistry. I would advise researching them to at least gain an understanding of what is good practice in this regard and realizing that just because one can does not mean one should. It may result in fewer houses burning down.
@nikhilpunalur
@nikhilpunalur 2 жыл бұрын
actually charging lithium ion battery with lead acid battery charger is safe. i dont know anything about lifepo4
@5_Is
@5_Is 2 жыл бұрын
@@nikhilpunalur You're much too modest: It's obvious you don't know anything about lithium ion batteries either. If you choose to use a lead-acid charger with the equalisation mode disabled to charge a lithium-ion battery, then you must disconnect the battery as soon as it is fully charged, to avoid damage to the battery. Best practice is to use the charger meant for the battery. Why someone would say otherwise and put your battery bank at risk is questionable.
@dreteyete7305
@dreteyete7305 2 жыл бұрын
Bms should protect from over charge and under charge. Over temp under temp.
@-Graham
@-Graham 2 жыл бұрын
I am teasing the idea of running my SMT-750i on lipo with a BMS specifically set to the expected low voltage conditions the Ups wants (luckily I can change them in this unit) but knowing that Lipos don't like to be stored fully charged I am thinking that an extra cell or 2 would help keep the "fully charged" voltage closer to the storage voltage of the cells to increase longevity dramatically. I am still trying to work out a solution that would give me somewhat accurate run-time readouts on the UPS but it's very much a work in progress
@unwired
@unwired 2 жыл бұрын
There are UPS that has a limit in battery mode but there are that can work continuously. I have a IdealPower UPS that is now serving as an inverter. I just removed the mini speaker.
@jserenity
@jserenity 2 жыл бұрын
The reason your UPS shutsdown suddenly is because your bms have higher voltage cut off than your ups.
@mediatrix1111
@mediatrix1111 2 жыл бұрын
Nice Video. Have you experienced any drawbacks of using these LiFePo4 batteries instead of Lead Acid batteries in the last year and a half since you started using it? Thks.
@inspiredbygod8412
@inspiredbygod8412 2 жыл бұрын
This is not just an educational video but a motivational as will for he shows his mistake and still take video
@MrRajaramrajagopal
@MrRajaramrajagopal 2 жыл бұрын
I made a successful DIY Lifepo4 12v 32650 batteries to replace the lead lead acid battery of my APC 800.with 3S BMS of 40A. When tested UPS started with peeps amber lead., where as out put AC voltage is 275 v the.condition of batteries and BMS are normal. May I know the reason for high voltage?
@arturtrzebinski2112
@arturtrzebinski2112 2 жыл бұрын
I'm wondering how those two short-circuits influenced cells internal resistances. I was once replacing ni-mh cells in old cellphone's battery, and I shorted one cell for good 5-10 seconds. From that point on, this cell had significantly higher resistance than other two. The capacity didn't suffer significantly though. Just a thought.
@-Graham
@-Graham 2 жыл бұрын
Higher ESR will dramatically affect the capacity at high current draw. I assume you tested your shorted cell at a standard rate of 1A which may not show decreased capacity but certainly it will be reduced at higher loads
@upkarnewar2537
@upkarnewar2537 2 жыл бұрын
So the ups is gonna cut off before bms would cut off huh? Any method to mod ups ?
@user-qp2tn7fy7h
@user-qp2tn7fy7h Жыл бұрын
Hello great video could you tell me if you had any problems since you made it
@emperordragon7921
@emperordragon7921 2 жыл бұрын
you can now buy an exact size LiFephosphate as those in a UPS. will that work as well? I don't have the skills to build a battery cell as u did. thankx.
@bradrose7774
@bradrose7774 2 жыл бұрын
Looks like you got a nice 3rd degree burn on your finger. Am glad you used the BMS. Not sure how the BMS and the UPS work together on charging. You may consider putting a fuse in place to limit the amp draw as the UPS doesn't appear to have a fan. Have heard that you need to manage the heat output on the UPS to keep it from overheating (because of no fan). Have seen others recommend limiting UPS to 20% of capacity to mitigate heat build up .
@WizzRacing
@WizzRacing 2 жыл бұрын
The speed at which he yanks the pack out, Is nothing but astonishing..
@JonahtanAlexis87
@JonahtanAlexis87 2 жыл бұрын
Hello, you can create one for a 24v UPS with 8 batteries, I have the 8 batteries and the BMS lifepo4 8s 24v bms, but I don't know how to make the connections for the bms ???
@puriwatw.1323
@puriwatw.1323 3 жыл бұрын
Thank you so much
@pwdrhrn
@pwdrhrn Жыл бұрын
Hilarious short circuit fire! but this is EXACTLY what I need to do - thankyou and I'll be sure to insulate the terminals. You could easily just add an external, larger battery the same way I expect. Nice work. And Lithium battery voltage is very constant, until it hit's 10% or so left, then it plummets. Lead Acid is a longer curve down.
@tanishqbhaiji103
@tanishqbhaiji103 Жыл бұрын
Do not use a larger battery than the original because the UPS will overheat as they not designed for continuous use
@hjsuu7321
@hjsuu7321 2 жыл бұрын
Will the UPS give a accurate uptime and capacity estimation after replacing the Lifepo4 batts? Vital for UPS with automatic shutdown.
@Cabinlab
@Cabinlab 2 жыл бұрын
My APC with expanded capacity gives very inaccurate uptime and capacity estimates. However, it seems to only use actual battery voltage to determine state of charge, so automatic shutdown basically works as expected.
@BUCURPOPA
@BUCURPOPA 9 ай бұрын
Hi. Is the UPS still holding up?!
@richiesalvador9457
@richiesalvador9457 8 ай бұрын
yep. still using it til these days.
@gunavinoth2826
@gunavinoth2826 2 жыл бұрын
Good explain thank you so much
@debmalyaghosh4678
@debmalyaghosh4678 2 жыл бұрын
I have 2 UPS with 12 Volt 5AH Lead Acid Batteries and 12 Volt 7AH Lead Acid Battery, if I buy these Batteries then in the 5AH UPS the 6AH Lithium Batteries will probably undercharge, and in the 7AH UPS the 6AH Lithium Batteries will probably overcharge, what to do and why did not you use the Battery Case ??
@Chronizoul
@Chronizoul 4 ай бұрын
Just to help you on your future battery projects, BMS Leads should all have equal lengths.
@Andy-df5fj
@Andy-df5fj 2 жыл бұрын
The 15 amp BMS at 2:30 will provide only 190 watts or VA (12.7V X 15A).
@cricketol
@cricketol 3 жыл бұрын
should add a mppt solar charge controller also to it but . #NOTE make shore it can be programed to the right voltage so not have issues with the ups charger . test the max voltage of the battery at all times to see if it has a equalization charge so you dont blow up the battery / cells. other then that ill hope to see that you made an update of this ups conversion
@Mr.Thanos_
@Mr.Thanos_ 3 жыл бұрын
For 2000va 24v ups, How many battery i need and what Amp bms for say almost 500w load for at least 10 min ? Plz answer bro. I have this Power Guard PG-2000VA UPS which has a Display buit in and can hold 4 lead acid battery which is total of 24v 18ah.
@richiesalvador9457
@richiesalvador9457 3 жыл бұрын
8 cell in series(3.2v each) - 6ah. Your UPS can carry upto 1400watts. So you can add more battery in parallel of up to 50ah.
@Mr.Thanos_
@Mr.Thanos_ 3 жыл бұрын
@@richiesalvador9457 What about BMS ? Which bms i should choose ?
@richiesalvador9457
@richiesalvador9457 3 жыл бұрын
@@Mr.Thanos_ based it on the max ah capacity of your battery build. For 18ah, you can use 20-30ah bms
@Mr.Thanos_
@Mr.Thanos_ 3 жыл бұрын
@@richiesalvador9457 Thnx bro now i get it. Soon I'm gonna do it. If i need any help i will ask you.
@g-teche-tech7004
@g-teche-tech7004 Жыл бұрын
@@richiesalvador9457 I ve seen a BMS with contact relay programming. You set charging voltage and over charging voltages from 6v to 60v, do you think it's safe to use that BMS. I am afraid the transistor BMS may short one day and cause fire.
@waynewilliamson4212
@waynewilliamson4212 2 жыл бұрын
great video....I have lots(15+) apcs that I have to keep replacing the batteries. I think I will try this on the next one that fails.
@richiesalvador9457
@richiesalvador9457 2 жыл бұрын
Go for it! You'll never regret! Mine's still working with 30-40 minutes backup time with my iMac with only 4 32650 batteries.
@songsoftime9115
@songsoftime9115 Жыл бұрын
​@@richiesalvador9457 Any overheating issues without a cooling fan for a that running time?
@WizzRacing
@WizzRacing 2 жыл бұрын
You have to change the Macs power down features.. As they are manually set..As APC does not make a PowerChute application that runs on a Mac...Without hacking the through the terminal window..
@user-zg3nb1mk5b
@user-zg3nb1mk5b 2 жыл бұрын
Are you sure you did the right thing ?! I think the bms input voltage is exactly 12.6 volts. And in the old battery it is charged between 13.8 and 14 volts. Can't your bms burn or more ?! By the way I thought to put some diodes directly to the ups, and put an external charger of 12.6 volts. I would be happy if you answer me in full detail.
@vufirst
@vufirst 2 жыл бұрын
Hmm, I am not sure I agree. From reading about these, the UPS are charging at a lower voltage while the LiFePO4 batteries need at least 14V to be charged properly. This means the new LiFePO4 batteries are under used..never fully charged and can only be used 50% instead of 80% of their capacity.
@user-zg3nb1mk5b
@user-zg3nb1mk5b 2 жыл бұрын
@@vufirst Thanks for your reply, could you kindly answer me another question please? If I use 1860 cells (no matter how many cells for now) including a suitable BMS, what do you think? Do 3 cells = 3.6X3 or 3.6X4? For UPS of course. (Instead of a 12V battery 7Ah)
@douganderson7412
@douganderson7412 2 жыл бұрын
@@user-zg3nb1mk5b 4 cels
@ooglek
@ooglek 2 жыл бұрын
You could put a buck converter on it and adjust it to the exact input voltage that your BMS requires. Most BMS allow for some range of input voltages though.
@mikes6216
@mikes6216 2 жыл бұрын
@@ooglek The charge wire is the same as the load wire, so it is impossible to use a buck unless you smash the charging circuit out of the UPS
@williammchugh4361
@williammchugh4361 2 жыл бұрын
At the prices the components are currently at for the build, I'm not sure this makes sense. Probably better off going with an external lead acid battery of much higher capacity which could have it's water levels checked. $60-$70 for this (following supplied links and some known pricing) seems pretty high, not to mention the unknown reliability factor of overseas components. I can get a 12 volt utility battery right now for $20 that will plug right in and work - although it will not fit in the case because it's a much larger battery.
@bobforte9343
@bobforte9343 Жыл бұрын
Correct. Too many incompatible pieces to fix safely. Pb might be low useable Depth of Discharge and not so great Cycle Life even with very conservative 100-60% DOD but it can be dirt cheap if you shop around and don’t buy new.
@zeuszaku
@zeuszaku 3 жыл бұрын
Is there any update on how long it lasts after a full charge?
@richiesalvador9457
@richiesalvador9457 3 жыл бұрын
Still the same until now. 20-25mins with my 21 inch iMac
@zeuszaku
@zeuszaku 3 жыл бұрын
@@richiesalvador9457 So far no fire or explosions?
@richiesalvador9457
@richiesalvador9457 3 жыл бұрын
@@zeuszaku none so far
@zeuszaku
@zeuszaku 3 жыл бұрын
@@richiesalvador9457 Have you considered selling one of those with a higher capacity?
@richiesalvador9457
@richiesalvador9457 3 жыл бұрын
@@zeuszaku i’m using it personally. So no plans of selling it
@prashanthkb6101
@prashanthkb6101 3 жыл бұрын
Thank you so much this is the video I was searching for 1 Since its lead acid battery UPS battery will be continuously charging does battery will destroy or fire due to overcharging 2. This battery capacity is how much AH. Can layman like me try to build battery of course i wont do short like you did And please let me know the how is your battery performance now
@richiesalvador9457
@richiesalvador9457 3 жыл бұрын
1. The BMS handles the overcharging. 2. 6Ah 12v in series. Battery still performs like the first day i installed it
@Bharani_0601
@Bharani_0601 3 жыл бұрын
@@richiesalvador9457 After the battery gets full recharge does the UPS cuts off charging ?
@richiesalvador9457
@richiesalvador9457 3 жыл бұрын
@@Bharani_0601 yes. The BMS has over charging protection
@douglundy5755
@douglundy5755 Жыл бұрын
very cool!
@lucybirb
@lucybirb 3 жыл бұрын
Honest Question: Doesn't the old case have its own BMS?
@richiesalvador9457
@richiesalvador9457 3 жыл бұрын
No. It was designed for lead acid battery not for lithium
@lucybirb
@lucybirb 3 жыл бұрын
@@richiesalvador9457 How would the case be able to tell since current is current?
@richiesalvador9457
@richiesalvador9457 3 жыл бұрын
@@lucybirb It does manage a 12v bat but it doesn’t mean it’s able to manage the 3.2v individual cells right? The BMS is for the 4 cells in series.
@lucybirb
@lucybirb 3 жыл бұрын
@@richiesalvador9457 I see your point. But if the battery(ies) where single 12V like this: www.vmaxtanks.com/V30-800-Deep-Cycle-High-performance-AGM-Battery-_p_46.html Then the UPS charger should charge it correctly you think?
@richiesalvador9457
@richiesalvador9457 3 жыл бұрын
@@lucybirb correct. It’s just like replacing the orig lead acid battery. No need for BMS. The reason why I use lifepo4 here is because of longer backup time and longer lifespan.
@bobforte9343
@bobforte9343 Жыл бұрын
“Charging normally”8:53 Oh boy can’t wait to see where this goes
@Ender_Wiggin
@Ender_Wiggin 3 жыл бұрын
Keep us updated i want to do that same just not sure it would be safe
@Landrew0
@Landrew0 2 жыл бұрын
Is much more safe to use 4 lithium cells to charge to 12 volts level. No danger from fire and lasting 10 years or more.
@g-teche-tech7004
@g-teche-tech7004 Жыл бұрын
@@Landrew0 This has been my concern, does BMS prevent the UPS charging system from destroying the Lithium batteries?
@waynewilliamson4212
@waynewilliamson4212 2 жыл бұрын
Hey, going on a year later...is it still working?
@richiesalvador9457
@richiesalvador9457 2 жыл бұрын
yes. im still using it
@danc2014
@danc2014 Жыл бұрын
FYI the actual battery use is only when the power is out. For small drops there will be little demand. Doing a performance test would be interesting to see if the capacity has change. or if the charger circuity was working correctly.
@en2oh
@en2oh 2 жыл бұрын
excellent video! only one suggestion: as good as your english is, Lead-Acid is pronounced Led-acid... as Pb in enlish is pronounced "led" not "Leed" otherwise, GREAT! any thoughts on how to increase the capacity limit ie increasing the 1050VA limit?
@richiesalvador9457
@richiesalvador9457 2 жыл бұрын
Regarding the Led vs Lead pronunciation, you're right. My wife already scolded me because of that. haha. I never thought of increasing the capacity. It was just an experiment so I can still use the UPS. But it would be a good idea. I'll see if I can find a way to do it.
@Middle-Eastt
@Middle-Eastt 2 жыл бұрын
What do you mean by "enlish"? 😃😃😃😃, We are more interested in the communication, not here for English class.
@jimbeam5
@jimbeam5 3 жыл бұрын
Umm, how long will it take for the UPS charger to kill the Lithium?
@richiesalvador9457
@richiesalvador9457 3 жыл бұрын
average of 3000 cycle. probably 3-5years. Not sure yet as this is an experiment. With the help of the BMS, hopefully it will last long :)
@jimbeam5
@jimbeam5 3 жыл бұрын
@@richiesalvador9457 My guess is the constant float charge designed for SLA batteries will greatly reduce the expected life cycle.
@adon8672
@adon8672 3 жыл бұрын
@@jimbeam5 the BMS prevents that from happening.
@jimbeam5
@jimbeam5 3 жыл бұрын
@@adon8672 BMS prevents Over Charging not constant charging.
@MAD4FAK4
@MAD4FAK4 2 жыл бұрын
@@jimbeam5 no, most BMS prevents constant charging. You can measure it with ampere meter, once the batteries are fully charged it cuts off the batteries. Even when you disconnect the whole unit, and connect it again, it checks for the batteries voltage and cuts them off again. My BMS also doesn't respond (starts charging the batteries) even if I use 3-4% of the batteries. It started charging them again when they reached about 90%.
@FirstLastOne
@FirstLastOne 2 жыл бұрын
Don't forget that if you ever turn your UPS on its end, side or upside down after a couple of days, that masking tape will do nothing to stop your batteries from moving around inside that UPS case.
@dash8brj
@dash8brj 8 ай бұрын
Yes I would have used 3m VHB double sided tape. I have a 200Ah 12V battery made up of individual 6kg LFP cells and the tape alone is enough to hold them together.
@arveenaval8033
@arveenaval8033 Жыл бұрын
better with active balancer....ang voltmeter to monitor the voltage of battery....for you to know if it is already low battery ....
@gopronomad4381
@gopronomad4381 Жыл бұрын
I knew something was wrong with the setup.. UPS requires high discharge battery source and PB acid battery allows for really thigh discharge for a short period, while LFP (lifepo5) has significantly lower discharge capacity so you'd need lots of parallels to make it effective.
@bobforte9343
@bobforte9343 Жыл бұрын
LiFePo4 can have pretty decent discharge rates. 3C to 5C is usually the continuous. I know the 38120 headway cells do quite a bit. Do you need 10C?
@tanishqbhaiji103
@tanishqbhaiji103 Жыл бұрын
UPS won't pull more than 3C continuous and deep cycle lead acid is horrific for high C loads, it won't deliver any capacity.
@abinkunjukutty2757
@abinkunjukutty2757 3 жыл бұрын
Similar scenario is happening to me "My UPS shuts down without warning and Battery BMS goes to OFF mode as well then I have to open UPS reconnect BMS wire only after that my UPS starts". Other than that UPS and Battery are functioning pretty normal.
@Bharani_0601
@Bharani_0601 3 жыл бұрын
Same thing happened to me. Did you find the solution?
@peacewillbetaken
@peacewillbetaken 3 жыл бұрын
The LFP (LiFePO4) batteries in this project have a low voltage cutoff of about 2.8v per cell, which is about 11.2v for the pack. Running it that low will shorten the longevity of your battery. If you have a BMS it will protect your battery by cutting it off at a higher voltage like 3v per cell or 12v for the pack. Either way, the UPS inverter which is designed to run on Lead Acid can run down to about 10.8v or even 10v. Its in that voltage range that it is designed to start beeping like crazy to let you know the end is near. With the new batteries, the UPS will never get to that point - thus no warning. There is a solution, cheap. Get a product called a 'screamer' for $2. Search for the term "RC Lipo Battery Low Voltage Alarm". Its used for drones, detects when the cell voltage drops too low and starts beeping like crazy when that happens. It is attached to the "Balance Leads" which are found on all RC batteries. You may have to solder wires into your pack directly. Look for directions on how to do this. Then you can set the desired voltage level, and perhaps stuff the buzzer with some kinda goo or whatever so its not so loud. Set the voltage level to something just above where the BMS will cut it off. Have fun.
@KuntalGhosh
@KuntalGhosh 3 жыл бұрын
Even the smallest ups can consume big currents. The bms will trip on over current protection. Remove the bms and only use a cell balancer. Add a fuse that is twice the rating of battery capacity in ah/hrs. Like if ur battery is 10ah then add a 20 or 15amp fuse. & Remember at 100w load at output will typically result in 120w input or about 10amps in 12v. If r using lifepo4 don't go below 15ah or 20ah..
@christopheralagasi2015
@christopheralagasi2015 2 жыл бұрын
Just add a reset switch(commonly open) and solder it to the BMS' -B and -P port. You will short it in simple word to revive your BMS. It is the nature of the BMS to cut-off the connection when it reached the lowest voltage settings that is why the current from ac cannot traverse to the battery to restore it and recharge it when the electricity restored. Bore a hole for the reset switch at the back of the ups or on top of it just like mine. Make sure to long press it until you here the tick sound after the long beep to revive it.
@DesmondNoel
@DesmondNoel 3 жыл бұрын
Voltage drop of sharper than lead acid
@immrnoidall
@immrnoidall 2 жыл бұрын
go to wallmart and get a 105 amp hour deep cell lead acid for about $90 bucks and run that for hours and hours. We have a lot of outages here so I picked up a few of these UPS units for free. people trow them out rather than the hassle of buying a new battery and taring them apart to replace it. They are literally everyplace for free or next to nothing. when the lights go out, your stay on. lead acid can last up to 5 years if you check the water every month. The UPS units charge 24/7 and cook batteries. check water levels and cycle once a month.
@vufirst
@vufirst 2 жыл бұрын
From what I have seen, the lead-acid UPS batteries only last 2-3 years and most of them do not hold 80% of the charge after 2 years even though not being used much.
@immrnoidall
@immrnoidall 2 жыл бұрын
@@vufirst yup. they are battery cookers. you must check the water. walmart sells a deep cycle 100 amp hour. it is called a sealed lead acid but still has caps that unscrew to check water levels . because even sealed will vent off water . especially if just sitting on a needed "trickle charge". unused for 2-3 years. check water, cycle them once a couple month's or so, and use a real battery charger to charge it to full . most throw out ones you can get free, are not "pure sine wave" and not for lithium
@dvdrwsor
@dvdrwsor 3 жыл бұрын
Put an external switch for the speaker.
@richiesalvador9457
@richiesalvador9457 3 жыл бұрын
I might just solder it out next time. Thanks for the tip!
@HobkinBoi
@HobkinBoi 2 жыл бұрын
yeah i just ripped the piezo out of mine. I can mute it through software but i just don't want to deal wtih it and mine also tells me the battery remaining through the usb port so i don't really need the buzzer
@josephalbertmuyo6003
@josephalbertmuyo6003 2 жыл бұрын
Bms wire should have the same length.
@KuntalGhosh
@KuntalGhosh 3 жыл бұрын
You should remember that lifepo4 can only discharge at 1c continuasly and at 2c for few seconds. Using 6000mah cells is a bad idea. Ups will consume more than 15amp if u plug in a 100w load. And a 300w ups can consume upto 30amps. So u should go for 25ah lifepo4 at minimum. Or lithium ion. These batteries will explode or die early if u discharge them so hard..a monitor and pc st idle does not really consume much power. U should have run a cpu and gpu stress test to really see how long the battery takes to puffup😂
@polized123
@polized123 2 жыл бұрын
It is a Lifepo4 Battery. It can handle High Discharge Rate. Without getting hot. Plus lifepo4 batteries are very safe. It rarely catch on fire
@KuntalGhosh
@KuntalGhosh 2 жыл бұрын
@@polized123 yes they are safe and don't catch fire easily but the lifepo4 chemistry does not allow more than 3c or about 18amps in case of a 6ah battery pack for more than 30sec. Any more will shorten the cell life. Recommended discharge rate is 0.2c or about 1.2amps continue. And maximum 1c or about 6amps in this case continuasly. A typical 18650 lithium ion battery can be discharged at 20c or more. But lithium iron phosphate can not be discharged at more than 1c .. and him shorting out the battery by stupidly sticking it in the baremetal case without any protection has already damaged the cells a bit
@polized123
@polized123 2 жыл бұрын
@@KuntalGhosh yeah. That's why they are always configured in parallel. If we need high discharge rate for 12v. The configuration should be. 4s6p
@debmalyaghosh4678
@debmalyaghosh4678 2 жыл бұрын
I did not understand any of the term like 1C 2C, what are these?? If the 12 Volt 6 or 7 AH Lead Acid Battery is there by default then how can the UPS consume more than 15 AMP and why the UPS will consume more than 15 AMP if anyone connects a 12 Volt 6 or 7 AH Lithium Phosphate Battery ??
@9jmorrison
@9jmorrison Жыл бұрын
Links not expired
@Sammy213
@Sammy213 Жыл бұрын
haha, I hope your wife doesn't watch your KZfaq channel 🤣
@marklll8368
@marklll8368 2 жыл бұрын
pb is pronounced led
@borriskarlov8140
@borriskarlov8140 2 жыл бұрын
just so we are clear "Lead-Acid" refers to the metal LEAD (pronounced LED).
@richiesalvador9457
@richiesalvador9457 2 жыл бұрын
yeah. sorry about my pronunciation. you're correct :)
@en2oh
@en2oh 2 жыл бұрын
@@richiesalvador9457 ok, I forgot about the Missus….. If I’d realized that…. I would have sent you an encoded message! :). Good job on both counts, tho! (The video and the missus
@olvano
@olvano 2 жыл бұрын
🤣🤣🤣🤣🤣 nice control burnout
@amg11901
@amg11901 2 жыл бұрын
No,you can't replace the VRLA batteries with lithium batteries on your existing UPS. Lithium ion batteries have different charging regimes and voltages. If the UPS came with a standard gel type lead acid battery, it will have voltage regulation and charging cycles specific for that type of battery.
@WizzRacing
@WizzRacing 2 жыл бұрын
He is not using Lithium. He is using Lifepo4 batteries. Which are made for this application..
@skoneal007
@skoneal007 2 жыл бұрын
I know English has a lot of words that are hard to pronounce, Lead is pronounced Led like Led Zeppelin. Thats why they spelt it like that so it wouldn't be pronounced Leed. 😀
@richiesalvador9457
@richiesalvador9457 2 жыл бұрын
Yes got you
@bleeb1347
@bleeb1347 Жыл бұрын
I’m super surprised no one else is annoyed by how he is pronouncing “lead” as “leed” instead of “led.” No one else?
@-Graham
@-Graham 2 жыл бұрын
Some real schoolboy errors here. I am very surprised you didn't monitor the battery voltages as you tested it to get a better idea of how the unit is treating the cells. You are very lucky you didn't fry the PCB on the second short. I think the only reason you didn't have a VERY serious problem is due to using LiFe Po4 cells. Lucky escape! The UPS is expecting Lead Acid voltages to determine run time and shutoff levels which your BMS is not set to correctly. This whole project is good for a cheap & nasty way to get it to work longer but that's about it.
@igorberezin856
@igorberezin856 Жыл бұрын
You are pronouncing lead wrong.
@juntech..3440
@juntech..3440 3 жыл бұрын
you gonna burn all that battery and UPS dude ..put a insulator before anything dude for safety
@ctrlaltdebug
@ctrlaltdebug 3 жыл бұрын
Always take ring off when working with electrical.
@FirstLastOne
@FirstLastOne 2 жыл бұрын
If it smells like BBQ chicken when you're connecting up the batteries... you are doing it wrong. I bet you were awake after that.
@richiesalvador9457
@richiesalvador9457 2 жыл бұрын
Yep. Stupid mistake. I learned from it 🤣
@mikes6216
@mikes6216 2 жыл бұрын
DANGER!!!! If your UPS has not started your house on fire yet then it is only because of luck. I just tried the same setup using the same Daly BMS. Mine is a cyberpower pure sine UPS. The problem is the charging circuit is designed for a lead acid profile and it will not charge LiFePO4 batteries correctly. Lead acid chargers are over 14v and the maximum voltage tolerated by LFE batteries is 14.6V but this will SIGNIFICANTLY reduce their lifespan (more than 50%). If you charger runs over 14.6V (different for each UPS) then you run the risk of your battery offgassing to prevent an explosion. Since your charger doesnt realize this happened, it will just keep charging and charging until something catastrophic happens. Your cheap BMS doesnt cutoff the charging soon enough to keep the batteries healthy, it let's you charge then batteries up with the expectation that you are going to use them right away and not let them sit on the charger eternally. Now, here is where your house is at risk of burning down........ when MOSFETs on the BMS fail, they fail open. This means your BMS is no longer protecting your batteries and you will have no idea this happened. There is no alarm, there is no warning whatsoever. Your lead acid charger will just keep charging and charging your LFP batteries until there is a catastrophic failure. These batteries arent as dangerous as LiPo fortunately but you do still risk toxic chemical release offgassing (I dont know what happens when you abuse LFP batteries this bad maybe it is possible to start a fire). In my case with my UPS, it just did not work when I connected fully charged LFP batteries, I suspect the BMS shut off because the lead acid charger was trying to force too many volts- I will test it some more later today. The proper method is to learn how to disable the charge circuit, and connect an external charger that keeps each cell under 3.4V for longevity 3.2V is even better but this isn't a full charge. The external charger can be solar or electric, and it should support LFP battery charging profile. ** The proper way to charge these batteries is with constant current and slowly increasing the voltage as the battery charges **
@mikes6216
@mikes6216 2 жыл бұрын
You can use a diode to block the charger but this will cause some voltage loss. Maybe an Ideal Diode would be a bit more efficient but they will be expensive for most ppl's current draw. For only 120W you can get a 15amp ideal diode for under $30 but the specs on those seems to be false on aliexpress, they cannot handle nearly as much current as promised. Note: MOSFETs in your BMS may last for a couple years, but when they break down your LFP batteries will be instantly in danger.
@fvrrljr
@fvrrljr Жыл бұрын
it's spelled Lead but has two ways of pronounciations and two definitions. you're mispronouncing leed it should be pronounced "LED" lead VS leed. You did an awesome job, just that my ears cringed with wrong pronunciation. Death, dead VS deed, red, read VS reed, read and so on.... my goodness I've become a grumpy 'ol man "time for my meds!"
@alexsiniov
@alexsiniov 3 жыл бұрын
300w / 12v = 25 amps, i doubt your soldering will hold that power when UPS will be on battery. More solder wont hurt and be more safe :)
@DanielKennedyaeos
@DanielKennedyaeos 3 жыл бұрын
You're not converting all 25 amps to heat.
@alexsiniov
@alexsiniov 3 жыл бұрын
@@DanielKennedyaeos Not all 25 amps, but bad solder joint will create resistance. even if it eats 2 amps, 25w is a serious heat concentrated in several square mm and will cause sparks and melting
@r1ce0919
@r1ce0919 2 жыл бұрын
Does this mean the current depends on how much power the device consumes when connected to the ups? If ups only used in a router 9W-18W, then the current drawn from the battery will only be 1.3A-0.67A right?
@alexsiniov
@alexsiniov 2 жыл бұрын
@@r1ce0919 if battery is 12v then yes
@polized123
@polized123 2 жыл бұрын
Ups only consumes maximum of 10A. It should not have that problem
@immrnoidall
@immrnoidall 2 жыл бұрын
rip that beeper OUT. it is useless. you will know when it is going off.
@georgehanan1252
@georgehanan1252 2 жыл бұрын
Looks extremely dangerous setup.
@-Graham
@-Graham 2 жыл бұрын
Dangerous build too
@venzremoaguilar8251
@venzremoaguilar8251 3 жыл бұрын
After 1month of use i can pretty much tell it already exploded
@richiesalvador9457
@richiesalvador9457 3 жыл бұрын
Lol. Fortunately, it’s still working fine until today ;)
@venzremoaguilar8251
@venzremoaguilar8251 3 жыл бұрын
@@richiesalvador9457 i have many big ups in my storage idk if they will take lifepo so im researching if it explode or not. Btw thx for the info
@abinkunjukutty2757
@abinkunjukutty2757 3 жыл бұрын
I have been using same setup for an Year Now and I'm alive !
@ctrlaltdebug
@ctrlaltdebug 3 жыл бұрын
BMS will protect it.
@johnmorris3776
@johnmorris3776 2 жыл бұрын
06:57 Fireworks! 🧨
Why are people NOT buying raw LiFePO4 cells?
8:31
DIY Solar Power with Will Prowse
Рет қаралды 1,9 МЛН
LiFePO4 Battery Powered UPS
11:43
Bob's Adventure Time
Рет қаралды 3,3 М.
I PEELED OFF THE CARDBOARD WATERMELON!#asmr
00:56
HAYATAKU はやたく
Рет қаралды 24 МЛН
Зу-зу Күлпәш. Тайм аут. (3-бөлім)
43:54
ASTANATV Movie
Рет қаралды 455 М.
Monster dropped gummy bear 👻🤣 #shorts
00:45
Yoeslan
Рет қаралды 12 МЛН
Li-ion vs LiFePO4 Batteries: Advantages and Disadvantages
8:08
EbikeSchool.com
Рет қаралды 310 М.
Amazing Restoration Technique of an Old Lead Acid Battery
10:50
Wow Things
Рет қаралды 24 МЛН
SUPER UPS Battery Hack- Mikes Inventions
8:45
Mikes Inventions
Рет қаралды 252 М.
BATTERY TESTING GONE WRONG! Nermak 10Ah Test And Teardown
9:23
Ice Hole Power
Рет қаралды 16 М.
Budget 12V LiFePO4 Battery Showdown! Overpriced Garbage?!
12:45
DIY Solar Power with Will Prowse
Рет қаралды 269 М.
МОРСКИЕ РАЧКИ С ВАЙЛДБЕРИЗ ЧАСТЬ 3
0:50
Натали Макколи
Рет қаралды 3,2 МЛН
Normal vs Smokers !! 😱😱😱
0:12
Tibo InShape
Рет қаралды 19 МЛН
بروتين ريفولا معالج للشعر
0:16
Revola Expert Kozmetik
Рет қаралды 24 МЛН
Evolution of our product🤩 👆Get yours now link in bio🛍️👆
0:17
ОБУЧЕНИЕ ВОДИТЕЛЕЙ
0:18
В ТРЕНДЕ
Рет қаралды 12 МЛН
ЧАПИТОСИИИИК...🐾🐾🐾
0:14
Chapitosiki
Рет қаралды 6 МЛН