TXV Troubles... HVAC Service Call

  Рет қаралды 40,107

HVAC Tech Tips

HVAC Tech Tips

Күн бұрын

Пікірлер: 83
@juntang72
@juntang72 11 ай бұрын
I learned from someone that pulling out outdoor fan during whole system is running, head pressure should go up , low pressure stays same level for awhile, Txv is good. If low pressure goes up at meantime, telling Txv is bad. Thank you for sharing your knowledge with us.
@robertcherry4971
@robertcherry4971 3 жыл бұрын
Low air flow would of made your super heat low,not high.It has the correct amount of refrigerant,look at that sub cool.Let’s see good on charge but superheat is off....What controls superheat?TXV check why it is underfeeding. Even more so low air flow would of made your delta t higher .
@leonardbalaban8791
@leonardbalaban8791 3 жыл бұрын
Great, great video! thank you so much Josh for taking the time to record in such detail and explain. You’re a very nice and caring person!
@rocajive
@rocajive 2 жыл бұрын
Hey man I appreciate how to really explain and how you explain in detail what you do. New tech here and actually learning about txv has been a bit challenging
@wisdomwisdom817
@wisdomwisdom817 4 ай бұрын
Thank you so much for your time brother, , you are very kind and caring.
@hrdworkin7633
@hrdworkin7633 2 жыл бұрын
Great Video.....outstanding tip on verification of TXV trouble shooting!
@jrh86
@jrh86 Жыл бұрын
Great service call diagnosis very precise informative and useful...thanks bro 👍👍👍
@terrygrant8126
@terrygrant8126 2 жыл бұрын
Thanks for the fundamentals friend!
@ricoswavae512
@ricoswavae512 3 жыл бұрын
Definitely TXV it’s slightly restricted, that’s why you have a high subcool when you started to add more refrigerant you have more liquid outside on the liquid line because it can’t get through that TXV kind of backed up. Suctions low like you said and your superheat is slightly high. It’s pretty much starving the evaporator and stimulating sort of like a low on charge that’s also why your delta T is low, not enough refrigerant going through the evaporator.
@themrmoy40
@themrmoy40 Жыл бұрын
where are the videos Rico?
@jaimedpcaus1
@jaimedpcaus1 Жыл бұрын
I like the probes you're using. Cool video.
@Robyrich2377
@Robyrich2377 6 ай бұрын
Note for the official record, you should’ve taken the bulb off in the first place of the TV and put it in a warm bucket of water before adding refrigerant. That would be the simple solution to the problem as well is a timesaver as well.
@th-wt5pn
@th-wt5pn 3 жыл бұрын
Good video yeah i agree those txv have a mind of their own lol can’t wait to see the follow up video.. hvac for life lol 🤙🏽
@ChrisChrisKris-ol7vh
@ChrisChrisKris-ol7vh 2 жыл бұрын
Awesome video! I know I’m super late to the party but I agree the TXV is out of range and should be replaced. The only extra step I would have added is shutting down the system and watching the TXV equalize. Sometimes that will be a dead giveaway.
@SickaMorStyle
@SickaMorStyle 2 жыл бұрын
Can you further explain about equalization? Would it not equalize? I’m asking because I had one, and after I shut the system down for a bit I noticed there wasn’t equalization or it didn’t happen as quick as I thought it should. Thanks for the response
@SombraLocs
@SombraLocs 3 жыл бұрын
Great video!
@TheThorRs
@TheThorRs 3 жыл бұрын
i learned so much in this video. thanks lol
@sergiocruz5617
@sergiocruz5617 Жыл бұрын
Great explanation
@HVACTechTips
@HVACTechTips Жыл бұрын
Thank you 🙏
@actechformallyyomama746
@actechformallyyomama746 3 жыл бұрын
You did good on this. I’m sure people will learn proper techniques from this video. I’ll be a new subscriber. I have videos as well you can learn from.
@beefing313
@beefing313 Ай бұрын
Thank you b
@gas_man1565
@gas_man1565 2 жыл бұрын
good video, there was a better way of testing for the txv being bad. without wasting refrigerant. block the condenser and the SH shouldnt change if it does, then you got yourself a bad txv. very informative video. im a new subscriber. keep the videos coming.
@maxxflowtv876
@maxxflowtv876 Жыл бұрын
thanks, just learned this from a video I watched earlier today
@ziongiahn
@ziongiahn Жыл бұрын
Do you mean like covering the top of the condenser? Would it work if you disconnected the fan motor and taped a cardboard box ontop?
@jaybro1046
@jaybro1046 11 ай бұрын
@@ziongiahnyes, I think disconnect fan wire , to see the SH change
@butlerstouchHVAC
@butlerstouchHVAC 2 ай бұрын
@@jaybro1046what should happen when you disconnect fan motor?
@ryannapier7059
@ryannapier7059 2 ай бұрын
Disconnecting the old fan will make your pressures spike fast, I would rather put something on top to block the fan
@alejandromorales8359
@alejandromorales8359 2 жыл бұрын
Great video
@armandopineda5148
@armandopineda5148 2 жыл бұрын
Thanks
@SombraLocs
@SombraLocs 3 жыл бұрын
Those Fieldpiece wireless probes look nice, but it would be nice if they had bigger temperature clamps.
@stevencarrillo3615
@stevencarrillo3615 3 жыл бұрын
I also learned a lot thanks the video was 👍
@lucaswhite3411
@lucaswhite3411 Ай бұрын
You could also as a precaution check the temperature across your filter dryer. Looks like a small liquid restriction, possibly from someone not purging the system and not brazing with nitrogen causing oxidization that could clog the txv screen, or the filter dryer. Sensing bulb may also not be secured properly or insulated. That said looks like your on the right track.
@markkoppisch705
@markkoppisch705 3 жыл бұрын
great info, i heard of putting the txv bulb in hot water not cold.
@edwardgarza5104
@edwardgarza5104 2 жыл бұрын
You can do both hot or cold. Hot water would open txv to allow more refergerant in causing lower super heat, cold water would close valve causing superheat to raise
@CarlosEduardo-ci6iz
@CarlosEduardo-ci6iz 11 ай бұрын
Would this also work on elctrinic sensors?
@kcomfortsystemshvac7060
@kcomfortsystemshvac7060 3 жыл бұрын
Great video,,,,i think the TXV ,,non modulating how is should be,,,,!,,,
@hvacworkshop4791
@hvacworkshop4791 11 ай бұрын
I have never seen a blower fan capacitor of 40 MFD. Usually 5-10. 40 is like the size of the compressor
@itsnotfar
@itsnotfar Жыл бұрын
Thanks for showing the numbers. Most youtubers don't or will show on a tiny cellphone. Dang, you got nice tools for the job. Maybe some day I will too. What do you think of putting the txv bulb in cold water then hot to see if its adjusting.
@melvinwillingham233
@melvinwillingham233 3 жыл бұрын
you should have a 9/16 wrench for the flare nuts. I’m old school and never use pliers on nut and bolts.
@zacharyreed45
@zacharyreed45 2 жыл бұрын
I use an Xtra small crescent brand adjustable wrench, it's the most ridiculous $12 but, somehow I find a way to use it everyday.
@salvenezia1817
@salvenezia1817 2 жыл бұрын
Why do we always have to give our two cents. Let the man do what he wants. It’s not wrong.
@smacleod69
@smacleod69 Жыл бұрын
I can see a huge problem on that furnace. The return should came in from both sides of the furnace. With that filter as dirty as it is raises static pressure and lowers CFM and can simulate a bad TXV.
@biblebloopers946
@biblebloopers946 3 жыл бұрын
I'm 7 minutes in and screaming that you're super heat is high. How could you have an airflow problem? But i knew you would figure it out
@salvenezia1817
@salvenezia1817 2 жыл бұрын
We got a smart guy. Come on. We all think different. Ian’s it’s fine. Just because you saw that fast. All you can see is his screen. He was probably looking at other things. We always want to show that we are smart. Instagram humble ourselves and maybe even say I learned something today. Or at least give a compliment or great video.
@Rccrdawgs
@Rccrdawgs Жыл бұрын
Low air flow definitely would make everything colder...refrigeration 101
@user-hu4hx6bm6m
@user-hu4hx6bm6m 2 жыл бұрын
Piston should be charged by superheat . Txv by subcooling. Your delta T is 11 it tells you right away you have a system restriction. Filter dryer, or system contamination or . You must check first if all your mechanic components are clean then see if you have a piston or TXV . You cant charge or measure a TXV system based on superheat it have to be on subcooling.
@original8879
@original8879 23 күн бұрын
You know….. This TXV n 410A Have caused more problems n forced homeowners to spend more money…. Pain and frustration. Of course it keeps field technicians busy…but not all technicians have adequate knowledge of how to address n fix it…. Specially in sunbelt area it’s not easy to work in hot 100+ attic. To a point it’s not worth it!
@ParabellumX
@ParabellumX Жыл бұрын
I would've checked airflow first before checking the charge, but that's just me. After all, EAR. E-lectrical A-ir flow R-efrigerant Great video otherwise. Keep 'em coming. 😏
@michaelharris1653
@michaelharris1653 Жыл бұрын
Test txv. Disconnect cond fan and watch to see if txv modulates as it should.
@sdsd4284
@sdsd4284 5 ай бұрын
What should happen at that moment
@JOSERization
@JOSERization 3 жыл бұрын
Measure quick is way better for probes you should try it out
@sknight0391
@sknight0391 3 жыл бұрын
Older Lennox furnaces loved to use those big ole 40 mf'ers . Ever since the pulse furnace days. Good diagnosis. 👍
@renecuevas4128
@renecuevas4128 Жыл бұрын
Lennox old furnace with 40 mfd blower cap. Wow never seen it that high.
@mikemalone6103
@mikemalone6103 6 ай бұрын
First, never replace a Capacitor with the one you pull out, that might not be the right one in there. Get the data off the motor tag. Secondly, the superheat is much too high. See if the TXV has an adjustable post, it just might be just a bit of spooge in it. The test with the bulb is to put it in your hand to warm it up, fooling the TXV to feed and then see if the superheat comes down. However, the diagnosis was correct, Weak TXV, …
@godz1llaki11azzzz3
@godz1llaki11azzzz3 2 жыл бұрын
Just had this problem literally today and same results normal to high subcool high superheat low delta T did a bulb test with the txv and turns out bulb had lost its charge
@allanbrito13
@allanbrito13 2 жыл бұрын
Looks like the sensing blub is loosing its charge and causing the restriction
@carlviele4228
@carlviele4228 25 күн бұрын
What brand of tools are you using
@jeremyg8568
@jeremyg8568 Жыл бұрын
I know I'm late to the video but shouldn't you try the cold/warm water first to try and free it up?
@ArcolaBridge
@ArcolaBridge 6 күн бұрын
Is it possible to clean a txv? Or do need replacement?
@davidbotello7383
@davidbotello7383 2 жыл бұрын
What type of brand is that
@troyb9609
@troyb9609 2 жыл бұрын
You can pull the power wier on the condinsing fan and watch the hi side pressure climb and the suction line pressure will stay the same indicates a bad txv
@HVACTechTips
@HVACTechTips Жыл бұрын
That’s a great way of doing it. I’ve never been shown that or thought of it. Thank you!! I’m gonna give it a try.
@butlerstouchHVAC
@butlerstouchHVAC Жыл бұрын
can you explain to me how to check for a bad txv? new tech learning need better understanding
@5822huron
@5822huron 3 жыл бұрын
Look at your suction temp also.. thats a dead giveaway
@HNIC86
@HNIC86 3 жыл бұрын
I've heard those TXV goes out faster
@jamesgutierrez8606
@jamesgutierrez8606 2 жыл бұрын
It's wise to discharge the capacitor B4 checking it thanx brainiac out🤔🤪
@miguelperdomo786
@miguelperdomo786 Жыл бұрын
If you want to know if your txv is working, you need to change conditions. The easiest way is to disconnect the outdoor condenser fan, a properly working txv will keep superheat and suction pressure the same or just a little higher. But if it begins to climb then txv needs replacement.
@redneckways1617
@redneckways1617 5 ай бұрын
Could be as simple as bad bulb placement
@TheThorRs
@TheThorRs 3 жыл бұрын
I guess i wanna ask the chat here if anyone could help me out if thats ok. How does one know which pressures are appropriate? is it like written on the/a general rule of thumb that your suction and head pressures should be or is it some calculations needed. I can just google this but i see so many different answers and methods it gets kinda overwhelming to filter. Thank you
@HVACTechTips
@HVACTechTips 3 жыл бұрын
There is a general idea for the right suction and head pressure according to which refrigerant you’re using. Although sub cooling will change depending on the manufacturer. And superheat is always figured by a general chart.
@HVACTechTips
@HVACTechTips 3 жыл бұрын
Arrange for suction and head pressures will also go up and down depending on the temperature outside. It can get a little confusing LOL
@erichorton1440
@erichorton1440 Жыл бұрын
Wow, an hvac video that wasn't recoreded with a potato.
@vatslavorlov7441
@vatslavorlov7441 11 ай бұрын
someone explain it to me; i thought with a TXV it tries to hold superheat constant, so why would adding it here result in a change? and how does that help to diagnose a restriction here
@gabrielblake4191
@gabrielblake4191 27 күн бұрын
Txv should hold constant, if it doesn’t then it’s not holding SH properly
@ares3914
@ares3914 Жыл бұрын
I hate residential equipment when the have txvs that are not adjustable. Txv is done bro.
@abcdefghi2175
@abcdefghi2175 Жыл бұрын
IS THAT A SNAKES RATTLER TO THE RIGHT I AM OUT OF HERE 🐍🐍🐍🐍🐍🐍🐍🐍🐍🐍 😱😱🚑🚑🏥
@HVACTechTips
@HVACTechTips Жыл бұрын
Lol I didn’t notice! I’ll have to go back and look. 🤦‍♂️
@jackcline1581
@jackcline1581 3 жыл бұрын
Can you just change the TXV to a piston an be done with it?
@HVACTechTips
@HVACTechTips 3 жыл бұрын
Yes you can and we will do that sometimes
@williamryan181
@williamryan181 Жыл бұрын
It depends on the system. Single stage condensers, yes you can. 2 stage and above, no. TXV is required to regulate super heat.
@renecuevas4128
@renecuevas4128 Жыл бұрын
40 mfd for a blower motor. Is it a 110 volts EFM. Cause here 20 mfd is used for 1 HP up to 25 nothing higher than that.,,,,,,,,I kno Lennox Furnace install 40 mfd from Factory
@alfonsobenitez8574
@alfonsobenitez8574 Жыл бұрын
The sound wasn't to clear. Maybe cause of the condenser. I had it full volume still couldn't hear it loud enough.
TXV Troubles Part 2- TXV Replacement
15:38
HVAC Tech Tips
Рет қаралды 14 М.
This Call Had Me Stumped | HVAC Service Call
8:04
HVAC Tech Tips
Рет қаралды 17 М.
Who has won ?? 😀 #shortvideo #lizzyisaeva
00:24
Lizzy Isaeva
Рет қаралды 62 МЛН
Was ist im Eis versteckt? 🧊 Coole Winter-Gadgets von Amazon
00:37
SMOL German
Рет қаралды 39 МЛН
Troubleshooting  the TXV
19:23
HVAC Service Mentor
Рет қаралды 46 М.
How hvac technicians diagnose bad TXV problems in the field?
7:13
Taddy Digest
Рет қаралды 59 М.
HVAC Not Heating Service Call Over-sized Furnace issues
24:06
Anti DIY HVAC
Рет қаралды 88 М.
How to Diagnose a Bad TXV for an Air Conditioner!
6:48
Travis Poe
Рет қаралды 57 М.
TXV Diagnosis On Carrier Heat Pump Not Keeping Up.
16:44
HVAC GUY
Рет қаралды 20 М.
You're wasting money on heating! Use your A/C!
17:11
Tech Ingredients
Рет қаралды 379 М.
Unit is not Cooling, No AC Service Call
12:37
HughesMan HVAC
Рет қаралды 8 М.
Best Father #katebrush #shorts
0:17
Kate Brush
Рет қаралды 17 МЛН
Every gift is valuable 🥰🥳👻
0:33
Ben Meryem
Рет қаралды 7 МЛН
Jatuh dua berturut turut
0:15
CIREBON VLOG JEH
Рет қаралды 42 МЛН
小天使和小丑离家出走#short #angel #clown
0:36
Super Beauty team
Рет қаралды 30 МЛН