Installing 3 EV Chargers In 1 Day!

  Рет қаралды 19,441

N Bundy Electrical

N Bundy Electrical

4 ай бұрын

Get 10% off Rhino Trade Insurance using code BUNDY10 at www.rhinotradeinsurance.com/quote
Ansell gloves i wear kzfaq.info?even...
Use code BUNDY25 at unilite.co.uk/product-categor... for 25% off
Use code BUNDY10 at www.expertelectrical.co.uk for 10% discount
Join this channel to get access to perks:
/ @nbundyelectrical
This video is for entertainment purposes only and is in no way intended as a guide or 'how to'.

Пікірлер: 124
@jibba771
@jibba771 3 ай бұрын
9:19 I’ve done it that way for years. Not a spark but used to fit cookers for a well know retailer. Also if you don’t pull the sheath completely off, when you cut the wire it keeps it all together. It’s a good method for 4/6 mm TE as you can bend the top and use it to twist the wires
@garythespark6295
@garythespark6295 3 ай бұрын
Really enjoyed this one. Mitch seems like a good guy, very positive and knowledgeable. Ive still never fitted an EV charger so enjoyed seeing it done in as much detail as you’ve shown 👍🏻
@chrishorrocks4882
@chrishorrocks4882 3 ай бұрын
I twist alarm and flex the same way! Get a really neat tight twist on the strands...
@cjkokay
@cjkokay 3 ай бұрын
That twist you done is what I've done for the last 30 years doing alarm cables.
@Joe90Gallagher
@Joe90Gallagher 3 ай бұрын
I thought when the post came and you picked it back up, it was going to be a perfect ‘oh look, the sponsor of todays video’ 😂 Missed a trick on that one. Also spat out my tea…when you said “you can fit your finger right up the main tails” Yes, i know, I’m a child! Nice to see you back on form ❤
@Fishbait075
@Fishbait075 3 ай бұрын
Yet, when i made enquiries for a CU replacement, and some minor work (single sockets to doubles). I was told that Nottingham-way was too far away for the Bundyman :(. Found a local guy, but by the time he was 90% of the way thru, was when I noticed after asking for RCBOs etc, he'd gone and replaced my aged Wylex rewireable mess, with a twin RCD board. Gutted.
@Longeno55
@Longeno55 3 ай бұрын
EV is gooien to get more popular so $$$ . All the best Nick!
@Sparkyjedi
@Sparkyjedi 3 ай бұрын
5 EICR’s a day, joke mate , what 1 bed ,bed sits . Not worth the paper they are written on , visuals and earthloops 😂😂😂 That’s why the respect has gone for testing correctly 👍
@NBundyElectrical
@NBundyElectrical 3 ай бұрын
Not saying I’m doing 5 a day but people do
@LeighWinspear
@LeighWinspear 3 ай бұрын
@@NBundyElectrical according to the software/hardware testing manufacturer I use, the record is 19 in one day........
@NBundyElectrical
@NBundyElectrical 3 ай бұрын
Wow 🫣
@LeighWinspear
@LeighWinspear 3 ай бұрын
@@NBundyElectrical indeed, The fact that no organisation is monotoring or correcting this is astounding.
@Sparkyjedi
@Sparkyjedi 3 ай бұрын
@@NBundyElectrical Wasn’t saying you were doing 5 a day mate 😀 just making a comment, but 19 that’s another level , no words . I wouldn’t be able to sleep at night
@peterprice8393
@peterprice8393 3 ай бұрын
Surely if the main fuse supplying the Henley block is an 100 or 80 amp the 10mm tail are way under size for that main fuse protection .
@TheRCBiker
@TheRCBiker 3 ай бұрын
No, because the tails are protected by the upstream overload current protection. The circuit will only draw a max of 32a, for which 10mm are sufficient. Why people find this so difficult to understand baffles me.
@brightsparkmid
@brightsparkmid 3 ай бұрын
@@TheRCBiker some people are unfamiliar with it but glad that some people do understnad what is right
@JensenPGATourDriven
@JensenPGATourDriven 3 ай бұрын
Great electrical goodness learning , Nick /Mitch 💼⚡️👊
@gadgetman36
@gadgetman36 3 ай бұрын
I like those compact WCED boards.
@NBundyElectrical
@NBundyElectrical 3 ай бұрын
Great little boards
@stealthmovements8569
@stealthmovements8569 3 ай бұрын
Perfect if the DB can't take any additional circuits 👌🏻
@marksmith-ew7ir
@marksmith-ew7ir 3 ай бұрын
Adding to the fresh work ,got to learn some where ❤
@Rich-Eclipse
@Rich-Eclipse 3 ай бұрын
Like the look of those wced units, currently installing the fusebox ev40 ax units, but like you said they’re a lot bigger. Also we’re guilty of the 25mm tails, 10mm from now on. Thanks for the tips 👌🏼
@brightsparkmid
@brightsparkmid 3 ай бұрын
I used to do the same ! I then came across these little gems of a unit ! Wouldn’t turn back now and cost wise they are sooo cheap at around £36 ! BARGAIN !
@mylesie8078
@mylesie8078 3 ай бұрын
Definitely a happier camper working with someone and having the craic..
@benhall7209
@benhall7209 3 ай бұрын
Does the Rolec have a built in O-pen ? Or PME detection ?
@cg18994chriso
@cg18994chriso 3 ай бұрын
Probably worth getting some jelly crimps for the Ct cables along smaller no need to.strip and cheaper than wagos
@brightsparkmid
@brightsparkmid 3 ай бұрын
Funny you say that ! I swapped out to them just a day ago !
@cg18994chriso
@cg18994chriso 3 ай бұрын
@brightsparkmid much easier, I'm from a telecom background and have used thousands other the years.
@AndyK.1
@AndyK.1 3 ай бұрын
9:46 I was taught that some decades ago 😮. At least it’s still out there
@brightsparkmid
@brightsparkmid 3 ай бұрын
It’s one of my favourite thing I took from when I was a young lad just starting out, 🎉
@330d5
@330d5 3 ай бұрын
On the 2nd install, do you have a link to the mini CU you fitted?
@NBundyElectrical
@NBundyElectrical 3 ай бұрын
www.wced.co.uk/metal-enclosures
@michaeldavies8799
@michaeldavies8799 3 ай бұрын
Running cables in Cavity 😢
@AndyK.1
@AndyK.1 3 ай бұрын
Neat though
@cliveramsbotty6077
@cliveramsbotty6077 3 ай бұрын
i'm more concerned about gas escaping into the cavity
@southcoastev
@southcoastev 3 ай бұрын
How do you find those WCED boards? Ive heard they have a high failure rate?
@NBundyElectrical
@NBundyElectrical 3 ай бұрын
Mitch said they are great. Not had one go yet mate
@Eggnog3000
@Eggnog3000 3 ай бұрын
Wced rcbos are junk, you'll be back swapping that rcbo within the year...
@robdavies9906
@robdavies9906 3 ай бұрын
Nice to see you using some black and yellow tools for a change. 😂😂
@NBundyElectrical
@NBundyElectrical 3 ай бұрын
felt sick
@haldo691
@haldo691 3 ай бұрын
​@@NBundyElectricalenvy will do that to you 😂
@brightsparkmid
@brightsparkmid 3 ай бұрын
He loved every moment of it !
@robdavies9906
@robdavies9906 3 ай бұрын
@@NBundyElectrical I get that when I'm handed something with Makita on it. 🤣
@joeypriestman6783
@joeypriestman6783 3 ай бұрын
Can you put 10mm into a Henley with tails that feed a main board from 100a main fuse? I know they’re 2 different boards but that’s like putting 1mm from a socket for a light without fusing the cable down.
@joesouthgate
@joesouthgate 3 ай бұрын
Yeah you can, the protection for the cable is just at the after the cable not before as it's fixed at 32a
@thattoolguy9432
@thattoolguy9432 3 ай бұрын
Yep as long as the run is less than 3 metres and fused down thereafter
@joeypriestman6783
@joeypriestman6783 3 ай бұрын
@@joesouthgate - but the Henley the 10mm’s connected to is 100amp?
@joeypriestman6783
@joeypriestman6783 3 ай бұрын
@@thattoolguy9432 - never knew that, 13 years and I’m still finding out new things! Appreciate that!
@thattoolguy9432
@thattoolguy9432 3 ай бұрын
@@joeypriestman6783 I don't think we ever stop learning.. part of the fun 🤣
@andyca15
@andyca15 3 ай бұрын
Finally got your head out of Savo's bog I see. That'll teach you not to mix Babycham and Appletinis.
@douglassanton6290
@douglassanton6290 3 ай бұрын
What was the make of the ev board you used
@NBundyElectrical
@NBundyElectrical 3 ай бұрын
not sure mate I said it at the beginning of the video bud
@joesouthgate
@joesouthgate 3 ай бұрын
WCED
@douglassanton6290
@douglassanton6290 3 ай бұрын
Looks like I’m watching the video on the way to work in the morning
@douglassanton6290
@douglassanton6290 3 ай бұрын
@@joesouthgate cheers
@adventuresofanathan
@adventuresofanathan 3 ай бұрын
Could you not use a spare way in the board or SHOULD the EV ALWAYS have its own separate board?
@jvoric
@jvoric 3 ай бұрын
Probs not, My charger was wired into a spare way in our board..
@brightsparkmid
@brightsparkmid 3 ай бұрын
So the charger requires Surge protection and also type A rcd protection, the age of the board makes it hard to sometimes retro fit these. It also helps to take the install away from the existing meaning we can issue a single certificate for just the EV Board. If there was a new style board that has surge or can be retrofitted it can be possible but also may be more costly
@adventuresofanathan
@adventuresofanathan 3 ай бұрын
@brightsparkelectricalmidla133 good to know, thank you I'm thinking of wiring an EV to my board - I just wanted to know if a separate board was a requirement.
@jason05121969
@jason05121969 3 ай бұрын
What make etc is the RCD surge etc .. nice small unit ..
@brightsparkmid
@brightsparkmid 3 ай бұрын
WCED
@jason05121969
@jason05121969 3 ай бұрын
@@brightsparkmid cheers .. which model NUmber if you don’t mind me asking .. look a lot more compact than the fusebox ones .. thanks again
@brightsparkmid
@brightsparkmid 3 ай бұрын
@@jason05121969 WMRC40CSP, no problem, they are super compact , 32 mm and 25m Ko top and bottom they are great to be honest
@markwestwood2016
@markwestwood2016 3 ай бұрын
How dare you not go to Jaspers Bakery!
@NBundyElectrical
@NBundyElectrical 3 ай бұрын
Lol you seen the size of the que 😂
@m8thy
@m8thy 3 ай бұрын
Saying Hold Tight now? @plumberparts rubbing off on you? 👀😂
@AndyK.1
@AndyK.1 3 ай бұрын
I think I even heard it on the TV!
@daveroberts3960
@daveroberts3960 3 ай бұрын
mate cant speak for domestic installs in a gas meter enclosure but no way is that allowed in comercial or industrial gas meter rooms
@imranhussain8474
@imranhussain8474 3 ай бұрын
I understand the purpose of bonding water and gas but why is there more emphasis on doing this during an EV install?
@KevinSmith-ph6jv
@KevinSmith-ph6jv 3 ай бұрын
Water and gas bond should be in place before any new installation
@Bradders-ez2nd
@Bradders-ez2nd 3 ай бұрын
Velocity is light years behind veto in every imaginable way possible. If you’re serious about your tools you should be buying vetos. Veto set the standard the rest are just trying to follow. Hence the 5 year zero downtime warranty compared to velocity’s 3.
@cjkokay
@cjkokay 3 ай бұрын
Nice wheres you hear protection and safety glasses. Oh yeah wheres your gloves
@cjkokay
@cjkokay 3 ай бұрын
There's a seat belt missing from mitch
@RGelectrician
@RGelectrician 3 ай бұрын
Bumblebee job?
@KevinSmith-ph6jv
@KevinSmith-ph6jv 3 ай бұрын
Nice vid! Although if it’s 100 amp main fuse you definitely need 25mm tails off that regardless of what it’s supplying. Otherwise with that logic you could say I’m going to wire in 1mm twin to the Henley block as it’s only supplying 1 led lamp… The cable always has to have a higher current capacity than the fuse it’s protected by
@Saaj2
@Saaj2 3 ай бұрын
Not true, the regs state you can have the overcurrent protective device downstream if cable length is under 3 metres (which it is). .
@matthewlynes8322
@matthewlynes8322 3 ай бұрын
@@Saaj2exactly just like a busbar chamber. Just like the feed to your house also there are no fuses on the branches under the road It’s funny all the opinions on this. It’s literally in the regs black and white
@trojanhawrs4613
@trojanhawrs4613 3 ай бұрын
You can't run unsheathed cores outside of an enclosure and Henley blocks aren't made for cables that small so no, you couldn't.
@KevinSmith-ph6jv
@KevinSmith-ph6jv 3 ай бұрын
@@matthewlynes8322Interesting to know! I just know whenever the DNO need to upgrade the fuse to 100 amp they always want to see 25mm tails outgoing before they do so
@trojanhawrs4613
@trojanhawrs4613 3 ай бұрын
@@KevinSmith-ph6jv although in that case they're upgrading because you need more power, so 100a is the design current. A standalone charger board is only ever designed to take the charger load
@alimack5489
@alimack5489 3 ай бұрын
How much does this fella charge per install cause I think I’m In the wrong game as a gas engineer 😂
@musthavetoolsforthetrade6436
@musthavetoolsforthetrade6436 3 ай бұрын
Oh dear using yellow power tools
@NBundyElectrical
@NBundyElectrical 3 ай бұрын
I know I know
@thattoolguy9432
@thattoolguy9432 3 ай бұрын
I can see Rueben singing Patti LaBelle -On my own , now Jordan has seen you can do 3 chargers a day, he'll bugger off on holiday and sack the rest of the crew 🤣 .. gotta ask the question on everyone's mind... whats your stance on the tool monster and Mikey incident?
@LeighWinspear
@LeighWinspear 3 ай бұрын
are you normally such a bitch or just confused and drunk?
@LeighWinspear
@LeighWinspear 3 ай бұрын
bitch comment.......
@artisanelectrics
@artisanelectrics 3 ай бұрын
👀
@richrowley8355
@richrowley8355 3 ай бұрын
Adams replacement is a bit more hairy....!
@brightsparkmid
@brightsparkmid 3 ай бұрын
Shorter and a bit heavier too !
@jacktissington
@jacktissington 3 ай бұрын
Im 3 chargers a day, no bother. I know there is a guy that does 5, but not for me. Ill stick with 3
@ryanbeach3616
@ryanbeach3616 3 ай бұрын
Used to work with him😂 he was sound , just the company we worked for was shite
@anthonybragg
@anthonybragg 3 ай бұрын
Jordan will be on the phone wanting you to work for him.
@NBundyElectrical
@NBundyElectrical 3 ай бұрын
£2k day , done
@artisanelectrics
@artisanelectrics 3 ай бұрын
😂😂😂
@calvinmcmahon2714
@calvinmcmahon2714 3 ай бұрын
That's why this industry is fucked
@thegingerhustle3173
@thegingerhustle3173 3 ай бұрын
Second comment I know But I really hope washed hands after toughing the dewalt rubbish 🤮🤮
@nicklight6561
@nicklight6561 3 ай бұрын
The poor man’s EV install nor sure why u have to have.a separate CU and so tight for space when you have a big garage wall and not use the existing board guess it’s full up! We find EDF flag all 10mm tails when they find them still in use wouldn’t want to put them to an 80A FUZE either
@brightsparkmid
@brightsparkmid 3 ай бұрын
Existing DB would not accept the required upgrades for a car charger, surge, type a RCD etc. Yes they will if it is supplying a whole property DB this is a load limited device, with whole home monitor CT clamp fitted, Downstream protection allows this as it is a method of protection as tails under 3m
@nicklight6561
@nicklight6561 3 ай бұрын
Spot on that !
@waynecollins1853
@waynecollins1853 3 ай бұрын
Promo-SM
@scoobyru84
@scoobyru84 3 ай бұрын
While I love your videos , really not a fan of you running the wire in the cavity . Any future person drilling through that wall or coring are in serious danger of injury had a mate that cored a wall and hit 100 amp cable supplying two flats above even after first core hole into cavity it was clear as coring outside wall wire dropped and bang it went he was seriously lucky to be alive .
@brightsparkmid
@brightsparkmid 3 ай бұрын
As long as RCD protection is in place there is no issue with it, you also must take into consideration that the charger is also a piece of electrical equipment so has its own zones for buried cable, same as a normal socket etc
@andrewgoldsmith532
@andrewgoldsmith532 3 ай бұрын
Very silent, across socials on velocity and loadout. Shame because I thought you were advocate for mental health?
@NBundyElectrical
@NBundyElectrical 3 ай бұрын
I’ve Spoken to Mike personally to see how he’s doing, I’m a huge advocate hence sharing my stories over the years, I’m currently dealing with a very close friend of mine again who is on the edge and is in a very very bad place. I’m there for people who need me and shouldn’t be made by anyone to voice my opinion on some thing I know little about especially all over social media
@ryang6572
@ryang6572 3 ай бұрын
@@NBundyElectricalwell said - some people….. hope your mate gets better soon.
@LeighWinspear
@LeighWinspear 3 ай бұрын
shame on you andrew. You and me are simply subscribers to a brilliant channel and should feel lucky that we receive posts/videos to learn from. Why do you feel that only you expect and deserve more?
@andrewgoldsmith532
@andrewgoldsmith532 3 ай бұрын
I am no KB warrior just genuinely interested in your view Valid point only the two parties involved know all the facts but Mike has been pretty clear in his responses My dad (who we recently lost) used to say actions speak louder than words therefore I wish you the best with toolmonster but I won’t be engaging I know more than most you need to put food on the table so I wish you all the best with that
@KRTCreativeOdyssey
@KRTCreativeOdyssey 3 ай бұрын
​@LeighWinspear a simple subscriber, is a person that has actually put Nicholas (the big man) where he is today! Without subscribers, Nicholas is nothing. So, it's right that his subscribers ask him about issues that he has been open about in the past, like online bullying, intimidation and mental health. Unfortunately though, Nicholas appears to remaining on neutral ground with the way Toolmonster has behaved towards Residual Current. This is probably due to them lining his pockets. On this occasions, condemning online bullying and speaking put about mental health doesn't suit Nicholas's narrative. Not Nick Bundy 100 bag, more like No B#llocks 100 bag. Unsubcribed.
I'm DeRegistering VAT
22:13
N Bundy Electrical
Рет қаралды 21 М.
This Was Terrifying - Supply Cable Blew UP
11:48
N Bundy Electrical
Рет қаралды 48 М.
Заметили?
00:11
Double Bubble
Рет қаралды 2,9 МЛН
Final increíble 😱
00:39
Juan De Dios Pantoja 2
Рет қаралды 11 МЛН
SHOCKING FIND - SO bad I had to fix it IMMEDIATELY
25:16
Artisan Electrics
Рет қаралды 188 М.
I Shouldn't Do It
17:09
N Bundy Electrical
Рет қаралды 17 М.
The IMPOSSIBLE Job...I Didn't Know If It Would Work.
13:35
SOTA Electrical
Рет қаралды 32 М.
9 EV Chargers. Which Is Best For You?
14:45
Nicolas Raimo
Рет қаралды 101 М.
What electrical work are you allowed to do in your own home?
10:39
Customer NOT Happy - Ripping Out My Own Work
8:38
N Bundy Electrical
Рет қаралды 59 М.
11,000 Volts BREAKDOWN ( The UK Grid is Struggling ) | ØY31
34:39
Cory Mac - ØY Electrical
Рет қаралды 82 М.
Is This Goodbye To The Ohme??  CHEAPER & EASIER To Install.
12:21
SOTA Electrical
Рет қаралды 10 М.
#чайбудешь
0:14
ЧУМАЧЕЧИЕ ПАРОДИИ
Рет қаралды 2 МЛН
Чья эта клубника ?
0:30
ЛогикЛаб
Рет қаралды 3,1 МЛН
Серебряное яйцо 😱   #спорим #физика
0:50
Polinka_girla (Полинка и Оператор)
Рет қаралды 1,3 МЛН
ПАРАЗИТОВ МНОГО, НО ОН ОДИН!❤❤❤
1:00
Chapitosiki
Рет қаралды 2,4 МЛН
Охрана года 😎 #кино #фильмы #сериалы
0:55