How to replace a leaking flow adaptor on a Worcester Bosch 24/28i junior / 25/30si

  Рет қаралды 11,349

Boilers To Bathrooms

Boilers To Bathrooms

3 жыл бұрын

A common fault on the Worcester Bosch junior and SI model is the flow turbines becoming brittle and break inside the return manifold, normally you see a drip coming from the right hand side or the boiler.
Here’s a step by step guide including the part number of the flow adaptor itself.
Hope this helps 🙏🏻

Пікірлер: 24
@NT-eh6om
@NT-eh6om 6 күн бұрын
Absolute legend, just saved me £200. Really easy job. My old adapter turned to crumbs as I removed it.
@macpatel7810
@macpatel7810 2 жыл бұрын
Very good video mate. Really helpful and well filmed showing important specifics too. Much appreciated.
@boilerstobathrooms6267
@boilerstobathrooms6267 2 жыл бұрын
Thanks for your feedback mate really appreciate it
@leaturk11
@leaturk11 2 жыл бұрын
That was quick, nice job sir.
@andyfireblade
@andyfireblade Жыл бұрын
thank you my friend. this video has really helped me today, your the best, regards andy
@woopsidaisy6712
@woopsidaisy6712 Жыл бұрын
This has been so helpfull , thankyou.
@lenboyd2357
@lenboyd2357 2 жыл бұрын
Thanks great help / my job for tomorrow with new parts.
@grainboy1
@grainboy1 2 жыл бұрын
Great video, help me so much
@boilerstobathrooms6267
@boilerstobathrooms6267 2 жыл бұрын
Thanks for the feedback much appreciated
@richienorthcott
@richienorthcott 9 ай бұрын
Super helpful. thanks. I can see a small leak on that side of the boiler, plus there are limescale deposits. Weirdly the water is dripping from the LHS of the boiler housing, but i think maybe the boiler isn't quite level so it's making its way to the other side via the valve bracket assembly? I can't see any leaks near where the drips fall from. Hmmm the drip is from the rear of the return manifold, not where the cold water pipe enters. Perhaps the whole return manifold needs changing out...
@greedo5120
@greedo5120 Жыл бұрын
I am so fucking happy you done this video!!!! I was struggling with that flow restrictor. I kept putting a washer between the black but and the white restrictor fucking god knows why... then I could actually get the clip in lol!
@greedo5120
@greedo5120 Жыл бұрын
Was my first return manifold today 🙃🙃🙃🙃🙃
@joejo4549
@joejo4549 8 ай бұрын
How important is it to keep the boiler clean of dust and possibly limescale?
@jimjim661
@jimjim661 2 жыл бұрын
excellent video. thank you
@boilerstobathrooms6267
@boilerstobathrooms6267 2 жыл бұрын
Thanks for your comment glad you liked the video
@rickwakefield3660
@rickwakefield3660 Жыл бұрын
brilliant video... cheers
@dylanwilde7003
@dylanwilde7003 2 жыл бұрын
that clip is so uneccesarily painful to put back in isn't it 🤦
@boilerstobathrooms6267
@boilerstobathrooms6267 2 жыл бұрын
Haha I hate the clip
@johncaufield760
@johncaufield760 2 жыл бұрын
@@boilerstobathrooms6267 Cut the clip in two, it still works. Tried and tested !
@user-ht2es7rx6i
@user-ht2es7rx6i 2 ай бұрын
Fuck that clip, its evil😢
@damiengriffiths8934
@damiengriffiths8934 Жыл бұрын
Been out to a Worcester 42 CDI classic today with low hotwater temp to outlets. Getting 41c max at first draw off….took dhw heat exchanger off. Descaled but wasn’t bad….back together and still only getting 44c max. Anyone experienced the same symptoms but caused by the flow adaptor? Cheers in advance
@boilerstobathrooms6267
@boilerstobathrooms6267 Жыл бұрын
Pretty sure you need to do a pcb reset on it mate that should do the trick
@damiengriffiths8934
@damiengriffiths8934 Жыл бұрын
@@boilerstobathrooms6267 I checked the range settings in the engineers menu and 100% on domestic hotwater and 70% on CH…. Naturally the plate is the first place to check with irregular temps but that looks fine and clean. I’ve been led to believe that the flow adaptor disintegrates allowing a higher litre per minute which the boiler can’t keep up with….I’ve done a couple of resets which takes it into a 15 minute initial start up but no difference….diverter seems to behave so don’t think it’s that either….wank boilers
Worcester Bosch Boiler Leaking - Leeds Plumber
32:41
Allen Hart
Рет қаралды 76 М.
Worcester Bosch 30si/28i junior flow adaptor replacement
8:53
Boilers To Bathrooms
Рет қаралды 6 М.
Inside Out Babies (Inside Out Animation)
00:21
FASH
Рет қаралды 13 МЛН
DEFINITELY NOT HAPPENING ON MY WATCH! 😒
00:12
Laro Benz
Рет қаралды 63 МЛН
DAD LEFT HIS OLD SOCKS ON THE COUCH…😱😂
00:24
JULI_PROETO
Рет қаралды 16 МЛН
flow turbine adapter
5:23
Geoffrey Needs training
Рет қаралды 29 М.
Worcester Greenstar - How To Change / Replace The Return Manifold / Block / Unit
28:53
Worcester Bosch right hand block change
8:47
CP Utility Solutions
Рет қаралды 22 М.
Flow Turbine adapter change on a Worcester Bosch
5:41
CP Utility Solutions
Рет қаралды 35 М.
Return manifold replacement for a Worcester Bosch greenstar 30si
18:05
Boilers To Bathrooms
Рет қаралды 16 М.
How to recharge an expansion vessel in a combi boiler
2:41
Ultimate Handyman
Рет қаралды 638 М.
Inside Out Babies (Inside Out Animation)
00:21
FASH
Рет қаралды 13 МЛН