flow turbine adapter

  Рет қаралды 28,955

Geoffrey Needs training

Geoffrey Needs training

4 жыл бұрын

leaking boiler how to fit a Worcester greenstar flow turbine adapter

Пікірлер: 45
@chrisn2279
@chrisn2279 2 жыл бұрын
Wow. I had the O-Ring in the wrong place and wondered why for 2 hours I couldn’t get the clip back in. Thanks for this video really helped me! Clip went back in nice and easy!
@edmetcalfe8974
@edmetcalfe8974 3 жыл бұрын
Got one of these to do later this week. I’m confident I could have figured it out but after watching this video I no longer have to. Looks very straightforward. Thank you.
@timhancock6626
@timhancock6626 2 жыл бұрын
Ed, the only problems I ever had were 1) giving a hard enough pull on the tab to get the old one out 2) the old one has sometimes broken in half leaving the back half stuck in the hydro block. I used needle point pliers to retrieve the remains, often in bits. You just need to sure you have got it all out so have a good look with a pen light or equivalent. Good luck. Most come out easily enough.
@icklepob88
@icklepob88 2 жыл бұрын
Thank you,great help this morning when mine failed and started leaking. Easy and inexpensive fix due to your help and advice in this short clip
@henrysiegertsz8204
@henrysiegertsz8204 3 жыл бұрын
Hi Geoffrey, I'm not a plumbing or Boiler engineer, but my plumber seemed flummoxed by my 4 year old Greenstar 38CDI. So much so I decided to diagnose the problem myself. (I have 40 years of troubleshooting experience in electro-mechanical and electronics). CH works fine, great flow, fast heat and spot on temperature control. DHW another story, Water runs hot for a few minutes then gets cold, then periodically gets luke-warm. I turned off the CH, by turning the control dial on the boiler to * (Antifrosting). Then I turned the DHW control to max and ran a hot tap. The boiler didn't fire up, no pump, no fan and no ignition. After a moment the boiler did start, but not immediately (Within 5 seconds it took a good minute) when presented with a DHW demand. I operated the ECO mode, and ran the hot tap once more, ice cold water and the periodic heating stopped. The periodic heating of hot water is preheat I believe, which maintains a small amount of water hot in the system to reduce transit time to the demand HW tap. This cycle is maintained by a thermocouple temperature signal and burner / fan modulation by the controller. All this tells me there is no demand generated to fire the boiler in DHW mode. The demand is generated by a small Flow turbine, which I believe in in series with cold water supply flow into the DHW side of the H/E. Since Preheat works and regulates correctly, I can assume the control system, DHW thermistor and diverter valve are all functioning correctly. (Diverter valve must be ok since the CH does not heat up when turned off and the hot tap is run) By my analysis of the symptoms, the fault lies with the Flow Turbine, either electrically or mechanically unserviceable, the, or the Turbine output signal not being processed by the control board? (So either the control board or the Flow Turbine sensor are U/S). I deduced all this with no test equipment, just the DHW Block schematic of the Boiler. Is my analysis path correct, are the components I suspect the most likely cause in your opinion? Because my Plumber wants to replace the Heat Exchanger. I expected him to call me this morning before he collects the H/E he ordered, but he hasn't.
@ridew3072
@ridew3072 4 жыл бұрын
Thanks for your advice on the phone earlier, Geoffrey - greatly appreciated. And top page! Brilliant selection of videos. I’m sure I’ll be leaning on them in the future. Cheers, Luke.
@grahameida7163
@grahameida7163 Жыл бұрын
I was amazed they chose a plastic that detereates for the old version of the flow adapter... great video to watch before the job, problably would have been fiddiling with it for ages to work out the new style of part !
@gonzalomartinez1630
@gonzalomartinez1630 4 жыл бұрын
Merry Christmas and a Happy New Year to you. Thanks for the great vids!
@milkyporridge5929
@milkyporridge5929 4 жыл бұрын
Your videos have saved me more than once thanks for your time
@manikalirai8953
@manikalirai8953 2 жыл бұрын
The best flow turbine vid, thank you so much
@mhpservices1
@mhpservices1 4 жыл бұрын
Cheers Geoffrey , Another out the park video. Thanks mate :-)
@ek6868
@ek6868 4 жыл бұрын
Tanx for the upload always enjoy your videos plz do some fault finding ones 👍
@fanyeros123
@fanyeros123 2 жыл бұрын
Thanks for this advice 😃,I'm new with breakdowns this should be really helpful.
@yensabi
@yensabi 4 жыл бұрын
Another great video Geoff , a happy and prosperous new year to you.....
@jonathanregis6136
@jonathanregis6136 2 жыл бұрын
Great vid never done anything like this before and I cant get a plumber so will give it a go today Thanks for the help ...Fingers crossed
@AdnaneLondon
@AdnaneLondon 4 жыл бұрын
Happy new year and thanks for sharing ...nice video as usual ...
@michellepoliquin4754
@michellepoliquin4754 3 жыл бұрын
thanks from canada .worked great..the clip was a bit fussy ..thanks again
@andyfireblade
@andyfireblade Жыл бұрын
thank you my friend. this video has really helped me today, your the best, regards andy
@oscaribarramartinez1033
@oscaribarramartinez1033 3 жыл бұрын
Good job from Spain
@russellheatingltddomestica5317
@russellheatingltddomestica5317 4 жыл бұрын
Professionally done
@edvinsteward6485
@edvinsteward6485 3 жыл бұрын
Thank you very much , you are great.🙏
@simonbeales7842
@simonbeales7842 4 жыл бұрын
Thanks for the vids
@paulrossiter9567
@paulrossiter9567 3 жыл бұрын
Love the tunes
@julianwebb8712
@julianwebb8712 Жыл бұрын
Yet another very good reason to buy a Baxi combi boiler…..or anything other than a Worcester lol 😂
@mehulkumarvpatel
@mehulkumarvpatel 3 жыл бұрын
Thanks very much.
@pagejamesuk
@pagejamesuk 3 жыл бұрын
Replaced mine as shown but still leaks but less so. O rings are correctly positioned. Does the flow sensor have o rings too?
@Morecocksthanhands
@Morecocksthanhands Жыл бұрын
So where did you put the white washer in the end that comes in the pack that was shown? Many thanks
@mikewilsonsmail
@mikewilsonsmail Жыл бұрын
On the cold water inlet - other end of the pipe you need to loosen/remove to get to the adapter.
@subscriptions6867
@subscriptions6867 2 жыл бұрын
I don’t have a leak, but Need to open Hot Water tap to Maximum to get the DHW to come on! Would replacing the flow turbine adapter help? Thanks!
@geoffreyneedstraining5856
@geoffreyneedstraining5856 2 жыл бұрын
There is a flow restrictor in the flow turbine adapter that may help that’s of course if you’ve got enough flow going into the boiler in the first
@paulhugh4645
@paulhugh4645 4 жыл бұрын
Hi, is that a CDI Classic you are working on, what are the symptoms of a faulty turbine adaptor. Thanks.
@milkyporridge5929
@milkyporridge5929 4 жыл бұрын
Paul Hugh no fire on hot water mode
@tswgas5553
@tswgas5553 4 жыл бұрын
When the water starts dripping onto the motor it will jam in one position either hot water position or Central heating this is not a CD it’s a junior but they’re all the same you will find some boiler got a green shield across the motor to stop the water dripping onto it
@MSKChess
@MSKChess 3 жыл бұрын
I have to remove and replace the entire return unit, what a pain in the a$$. Thanks Worcester, composite sucks. Video was very helpful never the less.
@Stillbusy105
@Stillbusy105 3 жыл бұрын
Did this one have a filter mesh in the cold water inlet, I didn’t see it in the video?
@geoffreyneedstraining5856
@geoffreyneedstraining5856 3 жыл бұрын
No there is no mesh on this flow turbine adapt
@geoffreyneedstraining5856
@geoffreyneedstraining5856 3 жыл бұрын
The actual strainer you’re talking about is in the cold water mains pipe not in the flow turbine adapter
@addiea2723
@addiea2723 4 жыл бұрын
Great videothanks so much. Hot watwe pressure has gone down after this. Why? Please help. Thanks
@addiea2723
@addiea2723 4 жыл бұрын
I havent chsnged the two part plastic filter thing that go inside the adapter in your video. Could that bd the problem? Does the boiler need some sort of bleeding for trapped air? Help plz
@nickhowse6063
@nickhowse6063 Жыл бұрын
can anyone tell me what the difference between the mk1 and mk2 diverter motor
@timhancock6626
@timhancock6626 2 жыл бұрын
The correct name for this component is " The Dissolving Flow Turbine Adaptor". The joke is the green diverter motor drip cover which WB put on instead of making the adaptor from better materials. Sometimes you can't make it up.
@reliabill87
@reliabill87 2 жыл бұрын
Can you do a video on what has cause or issue to replace the flow turbine?
@gedheaton1415
@gedheaton1415 2 жыл бұрын
sht Worchester plastics mate.
@captainbob8001
@captainbob8001 3 жыл бұрын
Good instructive video apart from the unnecessary mind numbing music.
@justsendmelocation5068
@justsendmelocation5068 4 жыл бұрын
I'm fitting one tomorrow, I hope the unit does have a pin hole or is split.
Flow Turbine adapter change on a Worcester Bosch
5:41
CP Utility Solutions
Рет қаралды 35 М.
МАМА И STANDOFF 2 😳 !FAKE GUN! #shorts
00:34
INNA SERG
Рет қаралды 4,9 МЛН
Smart Sigma Kid #funny #sigma #comedy
00:25
CRAZY GREAPA
Рет қаралды 17 МЛН
Жайдарман | Туған күн 2024 | Алматы
2:22:55
Jaidarman OFFICIAL / JCI
Рет қаралды 1,7 МЛН
Worcester Bosch Boiler Leaking - Leeds Plumber
32:41
Allen Hart
Рет қаралды 76 М.
Worcester Bosch 30si/28i junior flow adaptor replacement
8:53
Boilers To Bathrooms
Рет қаралды 6 М.
Is Your Central Heating System Losing Pressure?
6:43
Skill Builder
Рет қаралды 339 М.
compact  service strip down
9:00
Geoffrey Needs training
Рет қаралды 22 М.
replace a worcester plate heat exchanger and a pressure relief valve
5:31
Geoffrey Needs training
Рет қаралды 120 М.