How to replace a Worcester greenstar flow turbine or flow switch replacement including part numbers.

  Рет қаралды 11,967

MrHeatsmart

MrHeatsmart

5 жыл бұрын

Short simplified video from start to finish on replacing a flow turbine and checking workings and for leaks. With Recap and part numbers.

Пікірлер: 10
@matthewbuckyt339
@matthewbuckyt339 4 ай бұрын
Sweet cheers mate
@henrysiegertsz8204
@henrysiegertsz8204 3 жыл бұрын
You seem knowledgeable on WB Greenstar. I have a 38CDI. My Plumber is clueless, he thinks the DHW Heat Xchanger is blocked, but I did some troubleshooting. I took a look at the DHW Block diagram in the manual and checked the following. 1. CH, working perfectly 2. Hot water only runs hot for about 2 minutes 3. CH off, ran hot water, boiler not switching on when demand is present, Rads, not heating up, so Diverter Valve is OK. 4. CH off, and cold, ECO mode on. Ran HW, ice cold. Repeated several times absolutely no hot water in ECO mode. Conclusions So DHW preheat working, but after the pre-heated water used water runs cold and boiler doesn't Ignite, pump and fan not running. In non Eco mode (Normal) the boiler periodically starts up to regulate the pre-heat water temp, then switches off at the demand temp, so temp sensor is also OK. I suspect the Flow Turbine is seized or faulty. Not generating DHW demand to start the boiler. I'm not a plumber / Boiler Engineer and I've never worked on a boiler before, but I have 40 years plus troubleshooting experience.
@paulwilliams8536
@paulwilliams8536 Жыл бұрын
Was it the flow meter causing your fault? My boiler is showing same symptoms
@funtasticuk7772
@funtasticuk7772 2 жыл бұрын
Good Evening, My boiler has the exact same issue. Can I ask where you bought your replacements from please. Thanks Andy
@anthonywager2795
@anthonywager2795 4 жыл бұрын
I got a leak but its coming from the back of the housing near the heat exchanger. Could it also be flow turbine adaptor thats perished or does it alway leak from the front if this is the case?
@SurJones
@SurJones 3 жыл бұрын
Most likely either a Pin hole leak in the return manifold or bad O-Ring - Im sure you've gotten this fixed - Im replacing mine now.
@pagejamesuk
@pagejamesuk 4 жыл бұрын
Did you reuse the flow restrictor part into the new adaptor?
@MrHeatsmart
@MrHeatsmart 4 жыл бұрын
Hi, I replaced the flow restrictor also. Think it came as part of the replacement pair.
@pagejamesuk
@pagejamesuk 4 жыл бұрын
MrHeatsmart I used the original flow restrictors
@pagejamesuk
@pagejamesuk 4 жыл бұрын
MrHeatsmart do you think these adaptors could be hard to find in six years time (how long mine lasted)?
flow turbine adapter
5:23
Geoffrey Needs training
Рет қаралды 29 М.
Worcester Bosch Boiler Leaking - Leeds Plumber
32:41
Allen Hart
Рет қаралды 76 М.
Amazing weight loss transformation !! 😱😱
00:24
Tibo InShape
Рет қаралды 61 МЛН
Эффект Карбонаро и нестандартная коробка
01:00
История одного вокалиста
Рет қаралды 10 МЛН
Worcester Greenstar - How To Change / Replace The Return Manifold / Block / Unit
28:53
Worcester Bosch 30i erp flow manifold replacement step by step official video
9:51
Return manifold replacement for a Worcester Bosch greenstar 30si
18:05
Boilers To Bathrooms
Рет қаралды 16 М.
Worcester flow manifold
4:28
Geoffrey Needs training
Рет қаралды 25 М.
Flow Turbine adapter change on a Worcester Bosch
5:41
CP Utility Solutions
Рет қаралды 35 М.
Worcester Bosch 30si/28i junior flow adaptor replacement
8:53
Boilers To Bathrooms
Рет қаралды 6 М.
Amazing weight loss transformation !! 😱😱
00:24
Tibo InShape
Рет қаралды 61 МЛН